How to Load Images Manually into Segments in syngo.Breast Care
How to Load Images Manually into Segments in syngo.Breast Care
How to Manually Load Images into Segments in syngo.Breast Care 1. Select a patient from the worklist and double click to load study. SIEMENS Megan Thompson Server: 10.1.1.52 imi MAMMO MAMMO Last Name Date of Birth v + - . Accession Number Modality - MG Requested Proce ... Study Date and Ti ... Work Item Type ~ Read Work Item State > Ready, Suspended Workflow State Workflow Description Patient Name Patient ID Date of Birth Requested Proce .. Modality AZ @ Ready to read MG Breast XD CAD MG hilateral CZ 1/1/1067 MG bilateral MG SP O Ready to read MG Breast XP_Mag_Stand_bilateral .. 1118 1/1/2007 MG, MAG MG O Ready to read MG Breast AP_FIO_Ollateral, 2013 PT 10/10/1940 ZUTZ_MG DIlaterar MG D Ready to read MG Breast XP_Tomo_bilateral, 2013 T52 10/10/1979 MG, Tomo bilateral MG Ready to read MG Breast MG_Tomo_Inspiration_C ... T40 11/11/1958 MG bilateral+Tomo b ... CT, MG 2. Click on the small triangle at the right edge of the left high resolution monitor to open the “series navigator”. SIEMENS Megan Thompson Server: 10.1.1.52 MAMMO XP_Mag_Stand_bilat ... Other x MG Breast 1/1/2007 1118 MG Breast MG Reading Prior 01.Mammo.CVRMLO .* Prior 01.Mammo.CWLMLO .* Prior 01.Mammo.CWRCC .* Prior 01.Marmmo.CWLCC .* H. R.CC Findings Navigator R.ALO L.CC Name Value Source L ............ COP True Size Magnification: 0.2 True Size Magnification: 0.2 True Size Magnification: 0.2 True Size Magnification: 0.2 Original: 83 um, Displayed: Original: 83 um, Displayed: Original: 83 um, Displayed: Original: 83 um, Displayed: 1239 um 1233 um 1233 um 1239 um 7/31/2012, 3:52:49 PM, 7/31/2012, 3:50:35 PM, 7/31/2012, 3:46:59 PM, 7/31/2012, 3:48:39 PM, W/L 4096/2048 W/L 4096/2048 W/L 4096/2048 W/L 4096/2048 (WINDOW1) (WINDOW1) (WINDOW1) (WINDOW1) 11:21 AM .......... SIEMENS www.usa.siemens.com/healthcare 732 Effective 9/8/2016 Page 1 of 3 3. The series navigator will open showing you the studies that are loaded. Current MG, 8/22/2012 MG, MAG > CC MLO 4. Expand the study down to the image level by clicking on the triangle next to the view you would like to load onto the high resolution monitor. Current MG, 8/22/2012 MG, MAG CC > MLO * LMLO * LSMLO >R 5. Left click, hold down, drag, and drop the image you would like to view into the segment that you desire. Current MG, 8/22/2012 MG, MAG or 01.Mammo.CWLCC .* YL CC MLO * LMLO ILSMLO R SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 6. Repeat for all views that you would like view in the segments. 7. Close the series navigator by clicking on the triangle on the right side of the monitor. Prior 01 .Mammo.CWRMLO .* Prior 01 . Mammo.CWLMLO .* Prior 01 . Mammo.CWRCC .* True Size Magnification: 0.4 Original: 83 um, Displayed: 695 um 7/31/2012, 4:11:50 PM, W/L 4096/2048 (WINDOW1) True Size Magnification: 0.1 True Size Magnification: 0.1 True Size Magnification: 0.1 True Size Magnification: 0.1 Original: 83 um, Displayed: Original: 83 um, Displayed: Original: 83 um, Displayed: Original: 83 um, Displayed: 1839 um 1839 um 1839 um 1839 um 7/31/2012, 3:52:49 PM, 7/31/2012, 3:50:35 PM, 7/31/2012, 3:46:59 PM, 7/31/2012, 3:48:39 PM, W/L 4096/2048 W/L 4096/2048 W/L 4096/2048 W/L 4096/2048 (WINDOW1) (WINDOW1) (WINDOW1) (WINDOW1) SIEMENS www.usa.siemens.com/healthcare Page 3 of 3
- syngo.Breast Care
- Mammography
- Women's Health