How to Register Multiple Studies (Numaris X) Step by Step
How to Register multiple Studies (Numaris X) Step by Step
How to Register Multiple Studies (Numaris X) 1. In the Scheduler, select your patient with 2 or more registered studies. O Scheduler Search by Name, ID, DoB), Description, Procedure Date, Acc No: and Alodally (C. Q Patients Scheduled for Today (2 result(s), 7:07:04 PM) C Patient Y Procedure Date and Time Registration, Test *3/26/1998. 0 12345678 3/26/2020, 16:55 R Registration, Test *3/26/1998, O 12345678 3/26/2020, 19:04 2. Using the Control key, select both studies, then right click and select “Group”. Healthingers > O Scheduler Search by Name. ID, Doll, Descrittion, Procedure Date, Acc No. and Modality (C. Patients Scheduled for Today (2 result(s), 7:07:04 PM) Patient Y Procedure Date and Time Registration, Test *3/26/1998, O 12345678 Group Registration, Test Ungroup *3/26/1998, O Comptele Procedure 12345678 Discontinue Procedure ar Add Examination 12 Local Data Prior Studies Delete 3. Multiple procedures available is now displayed. Healthincers ) o Scheduler Search by Name, 10; DoB. Description, Procedure Date, Acc No. and AModalty (C Patient Registra Patients Scheduled for Today (1 result(s), 7:07:04 PM) Registratid Patient Procedure Date and Time * Last Nam Registration, Test *3/26/1998, 0 First Nam 12345678 3/28/2020, 18:55 Multiple procedures available Suff Middle Na Patient ! * Date of Bir Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 4. The multiple studies will be displayed in the upper right section of second page- Examination Information. In this example, Procedure 1 and Procedure 2. All Programs Examination Information Procedure USER Accession Nr. deleleme01 Reg Proc ID · Study Part DefaultStudyPart WorkflowSamilation Study Description WorldlowSimulation Hip Dot_Engine Bilateral . Ho_Dot_Engine_Bilateral Study Comment Hip_Dot_Engine_Biatera Procedure . C-Spine Dot Engine C. Spine Dot Engine Accession Nr deleteme02 Knee Del Engine Reg. Proc ID 29416ca6-5ce9-45 Abdomen Dot Engine . Study Part DefaultStudyPart · Heart Study Description WorldlowSimulation Hip_Dot_Engine_Bilateral . Whole Body Dot Engine Study Comment . Knee Dot Engine 20 Program Selection USER > WorkflowSimulation > Hip_Dot_Engine_Bilateral > Hip_Dot_Engine_Bilateral Load Program to Quede RF Transmit Mode Any Polarization Body Part and Laterality . Ho Right Patient Orientation Head First Supine Local Data Prior Studies Exam 5. Switch the view from Standard to Study Part. Healthineers Registration, Test * 3/26/1998 0 12345678 Hip Dot Engine + 1 AAHip_Scout Standard Image Comment 2 X_ 11_tse_cor_704_bilat 2 Body Part Study Part 3 pd_tse_cor_576_bilat 2 03:10 14 pd_tse_fs_cor_512_bilat 2 03:14 5 12_tse_fs_cor_512_bilat 03:14 16 12_tse_stir_cor_512_bilat 04:32 7 x t1_tse_tra_576_bilat 7 03:53 8 pd_tse_fs_tra_448_bilat 03:07 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 6. To add the next study, select the Add Program/Add Step by selecting the plus icon althineers Registration, Test * 3/26/1998 0 12345678 MR View&GO Hip Dot Engine 150€ Add Pro jra AAHip_Scout .. 1.2 Add Program / Add Step 22 2 x 11_tse_cor_704_bilat .. 1,2 03:46 USER 3 pd_tse_cor_576_bilat - 1,2 03:10 Q 4 pd_tse_fs_cor_512_bilat .. 1.2 03:14 5 t2_tse_fs_cor_512_bilat - 1,2 03:14 WorkflowSimu 6 12_tse_stir_cor_512_bilat ..- 1, 2 04:32 Hip_Dot_En 7 % t1_tse_tra_576_bilat .. 1.2 Hip_Dot_E 03:53 8 pd tse fs tra 448 bilat › C-Spine Dot ... 1, 2 03:07 7. Select individual sequences while holding the Control key or select a range by holding the Shift key Add Program / Steps USER > WorkflowSimulation >> Hip_Dot_Engin USER Q Standard WorkflowSimulation AAHip_Scout 00:22 AutoAlign Scout Hip_Dot_Engine_Bilateral Hip_Dot_Engine_Bilateral C-Spine Dot Engine t1 tse cor 704 bilat 3:46 › Knee Dot Engine O Generic Views › Abdomen Dot Engine pd_tse_cor 576 bilat 03:10 1 Generic Views > Heart pd tse fs cor 512 bilat 03:14 > Brain Generic Views > Whole Body Dot Engine 12_tse_fs_cor_512_bilat 03:14 > Knee Dot Engine 2D Generic Views t2 tse stir cor 512 bilat 04:32 Generic Views 11 tse tra 576 bitat 03:53 2 Generic Views pd_tse_fs tra 448 bilat 03:07 2 Generic Views Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 8. Add selected sequences by drag or drop method or by selecting the << icon. 1500 Add Program / Steps ... 1,7 00:22 USER > WorkflowSimulation >> Hip_Dot_Engine 2- 1,2 03:46 USER -- 1,2 03:10 Q V Standard -- 1,2 03:14 AAHip Scout 00:22 -.- 1, 2 03:14 WorkflowSimulation AutoAlign Scout | - 1,2 04:32 Hip_Dot Engine_Bilateral 2 .- 1,7 03:53 Hip_Dot_Engine_Bilateral .. 1.2 + 03:07 > C Spine Dot Engine 11 tse cor 704 bilat 03:46 Knee Dot Engine C Generic Views pd_tse_cor 576 bilat 03:10 Abdomen Dot Engine AAHip Scout Generic Views > Heart 03:14 3+ Copy pd tse fs cor 512 bilat Brain Generic Views Whole Body Dol Engine t2 tse fs cor 512 bilat 03:14 1 Knee Dol Engine 2D Generic Views t2 tse stir cor 512 bilat 04:32 Generic Views t1_tse_tra 576_bilat 03:53 2 Generic Views pd tsc fs tra 448 bilat 03:07 2 Generic Views 9. Select the series individually or select a range from the second study brought over Hip Dot Engine Add Program / Steps AAHip_Scout ... 1,2 00:22 2 X_ 11_tse_cor_704_bilat -. 1.2 03:46 USER 3 pd_tse_cor_576_bilat 1,2 03:10 Q pd_tse_fs_cor_512_bilat ·· 1.2 03:14 5 12_tse_fs_cor_512_bilat - 1,2 03:14 WorkflowSimulation 6 t2_tse_stir_cor_512_bilat == 1,2 04.32 Hip_Dot_Engine_Bilateral 7 _ 11_tse_tra_576_bilat - 1,2 03:53 Hip_Dot_Engine_Bilateral 8 pd_tse_fs_tra_448_bilat .. 1, 2 03:07 ›C-Spine Dot Engine Knee Dot Engine 9 AAHip_Scou - 1.2 00:22 Abdomen Dot Engine %_ 11_tse_cor_704_bilat 1 issigned to Requested Procedures 10 V 2 (MPPS) 11 pd_tse_cor_576_bilat 1. 2 1 - (deleteme01) WorkflowSimulation 12 pd_tse_fs_cor_512_bilat -- 1, 2 Hip Dot Engine Bilateral dy Dot Engine 2 - (deleteme02) 13 12_tse_fs_cor_512_bilat .. 1,2 WorkflowSimulation Engine 2D Hip Dot Engine Bilateral 14 t2_tse_stir_cor_512_bilat - 1, 2 04:32 15 x t1 tse tra_576_bilat - 1,2 03:53 16 pd_tse_fs_tra_448_bilat .. 1. 2 02.07 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 10. Select the Study Part that correlates to the second exam being scanned by deselecting the checkbox for the other exam shown Hip Dot Engine + 1 AAHip_Scout .. 1.2 00:22 2 % t1_tsc_cor_704_bilat =- 1,2 03:46 3 pd_tse_cor_576_bilat ... 1,2 03:10 4 pd_tse_fs_cor_512_bilat ... 1.2 03:14 5 t2_tse_fs_cor_512_bilat :- 1,2 03:14 6 t2_tse_stir_cor_512_bilat -- 1,2 04:32 7 t1_tse_tra_576_bilat .- 1.2 03:53 8 pd_tsc_fs_tra_448_bilat -- 1,2 03:07 9 AAHip_Scout 00:22 10 x t1_tse_cor_704_bilat 1 2 03:46 11 pd_tsc_cor_576_bilat 03:10 12 pd_tse_fs_cor_512_bilat -- 2 03:14 13 t2_tse_fs_cor_512_bilat -.- 2 03:14 11 t2_tsc_stir_cor_512_bilat -- 2 04:32 15 t1_tse_tra_576_bilat 03:53 16 pd_tse_fs_tra_448_bilat 03:07 11. Update the study part for the remaining series and studies Hip Dot Engine 1500 + 1 AAHip_Scout .. 1,2 00:22 2 % t1_tse_cor_704_bilat .. 1. 03:46 3 pd_tse_cor_576_bilat .- 1. 03:10 4 pd_tse_fs_cor_512_bilat ... 1. 03:14 t2_tse_fs_cor_512_bilat ... 1, 2 03:14 6 t2_tse_stir_cor_512_bilat - 1,2 04:32 7 % 11_tse tra 576_bilat ... 1,2 03:53 8 pd_tse_fs_tra_448_bilat - 1,2 03:07 9 AAHip_Scout - 2 00:22 10 x_ 11_tse_cor_704_bilat .. 2 03:46 11 pd_tse_cor_576_bilat .. 2 03:10 12 pd_tse_fs_cor_512_bilat .- 2 03:14 13 t2_tse_fs_cor_512_bilat .. 2 03:14 14 t2_tse_stir_cor_512_bilat -- 2 04:32 15 x t1_tse_tra_576_bilat - 2 03:53 16 pd_tse_fs_tra_448_bilat .. 2 03:07 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 5 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 12. This will route the series directly to the assigned study. Multiple copies will be made if more than one study box is checked Hip Dot Engine 1 AAHip_Scout 00:22 2 x_ 11_tse_cor_704_bilat . V 1 - 03:46 2 3 pd_tse_cor_576_bilat 03:10 4 pd_tse_fs_cor_512_bilat 03:14 t2 tse_fs_cor_512_bilat 03:14 6 t2_tse_stir_cor_512_bilat 04:32 7 % t1_tse_tra_576_bilat 03:53 pd tse fs tra 448 bilat ... 1 03:07 AAHip_Scout - 2 00:22 10 x t1_tse_cor_704_bilat - 2 03:46 11 pd_tsc_cor_576_bilat -.- 2 03:10 12 pd_tse_fs_cor_512_bilat 03:14 13 t2_tse_fs_cor_512_bilat 03:14 14 t2_tsc_stir_cor_512_bilat -.- 2 04:32 15 % t1_tse_tra_576_bilat - 2 03:53 16 pd_tse_fs_tra_448_bilat .. 2 03:07 A. When Study Part is correct for each sequence then select Standard view. Hip Dot Engine ISOe + AAHip_Scout Standard -. 1 Image ComnlAvit 2 x_ 11_tse_cor_704_bilat .. 1 Body Part Study Part 3 pd_tse_cor_576_bilat ... 1 03.10 4 pd_tse_fs_cor_512_bilat ... 1 03:14 5 t2_tse_fs_cor_512_bilat ... 1 03:14 6 t2_tse_stir_cor_512_bilat .. 1 04:32 7 %_ 11_tse_tra_576_bilat .. 1 03:53 8 pd_tse_fs_tra_448_bilat ... 1 03:07 9 AAHip_Scout ... 2 00:22 10 t1_tse_cor_704_bilat ... 2 03.46 11 pd_tse_cor_576_bilat .. 2 03:10 12 pd_tse_fs_cor_512_bilat -- 2 03.14 13 t2_tse_fs_cor_512_bilat ... 2 03:14 14 t2_tse_stir_cor_512_bilat ... 2 04:32 15 %_ 11_tse_tra_576_bilat ... 2 03:53 16 pd_tse_fs_tra_448_bilat .... 2 03:07 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 6 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 B. The series will be directed to assigned studies. Healthingers Registration, Test x * 3/26/1998 0 12345678 MR View&GO Patient Browser Local Data Seurch by Name, ID. Dale Description and Modality (Chit+F) More Filters Results (243 results, 7:18:03 PM) Patient Name Date of Birth Patient ID Modality Study Date a. Study Descript Registration 3/26/1998 12345678 MR SR 3/26/2020 7:1 WorkflowSim Registration 3/26/1998 12345678 MR SR 3/26/2020 7:1. WorkflowSim delete me 3/26/1998 delete me 123 MR. SR 3/26/2020 6: WorkflowSim. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 7 of 8 Job Aid: How to Register Multiple studies(Numaris X) Effective Date:05/05/2020 | HOOD05162003086683 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 8 of 8
- Numaris X