How to Use WorkStream 4D step by step

How to Use WorkStream 4D Computed Tomography 1. WorkStream 4D allows for the reconstruction of sagittal, coronal and/or oblique MPRs and thin MIPs directly in the Examination > Recon card without the need for thin, overlapped data sets or dedicated post-processing in the 3D card. 2. On the Examination Recon card, select 3D as the Recon job type. Recon job 2 8 8 4 8 8 Z 8 Series description Abdomen 5.0 SPO ax Slice 5.0 mm Recon job type @ axial € 3D IRIS Recon axis axial Kernel B30f medium smooth Window Abdomen Type SP oblique Image order Head to feet Position increment 5.0 mm = FoV 342 mm x 342 mm No. of images 41 Comments Routine Scan Recon | Auto Tasking 3. The screen layout will change to display coronal, axial and sagittal planning images. The pink box represents the desired FoV. The orange boxes represent the recon range and direction. Adjust these boxes to include the anatomy desired in the reconstruction. Rotate boxes as necessary to plan oblique ranges. TEST. PATIENT Hospital TEST. PATIENT Hospital TEST. PATIENT Hospital 01234567 01234567 01234567 *12-Sep-1962, M. 50Y "12-Sep-1962, M. 50Y *12-Sep-1962, M. 50Y 12-Sep-2012 12-Sep-2012 12-Sep-2012 18:15:14.39 18:15:14.39 18:15:14.39 MPR 2 MPR 2 MPR 2 A SL 5.0 300 SL 5.0 y 300 ¿ SL 5.0 SIEMENS siemens.com/healthineers Healthineers Job Aid | How to Use WorkStream 4D Effective Date: 8/16/2016 | Quality 344 4. If desired, a non-square reconstruction matrix can be defined to further limit the anatomy included in the reconstruction, e.g. for spines. Resolution 512 square Planning base Abdomen 5.0 B30f 512 square TEST, PATI512 non-square 34567 Total mAs: 1033 256 non-square(reduced image resolution) TEST. PATIENT Hospital TEST. PATIENT Hospital TEST. PATIENT Hospital 01234567 01234567 01234567 *12-Sep-1962. M. 50Y *12-Sep-1962, M. 50Y *12-Sep-1962, M. 50Y 12-Sep-2012 12-Sep-2012 12-Sep-2012 18:15:14.39 18:15:14.39 18:15:14.39 MPR 2 MPR 2 MPR 2 OV 120 x A SL 3.0 SL 3.0 SL 3.0 5. Additional reconstruction parameters should be defined on the Recon card, such as desired slice thickness and increment, image order, kernel, and the Type of image to be reconstructed (MPR or MIP Thin). These parameters can be stored in the protocol for future use. Recon job 1 2 8 4 5 8 7 8 Series description Abdomen 5.0 SPO sag Slice 5.0 mm Recon job type @ axial € 3D IRIS Recon axis sagittal Kernel B30f medium smooth Window Abdomen Type SP oblique Image order Left to right Position increment 5.0 mm FoV 126 mmx 326 mm 2 No. of images 26 Comments Routine Scan Recon Auto Tasking 6. Click Recon to begin the reconstruction of the 3D series. Recon Siemens Healthineers Services Page 2 of 3 Job Aid | How to Use WorkStream 4D Effective Date: 8/16/2016 | Quality 344 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3

  • as
  • flash
  • emotion
  • open
  • spirit