Innovision Audio and Innovision Display Systems
The job aid is an overview of the components including the installation of the patient display and table adapters.
SIEMENS Healthineers MAGNETOM Family - Innovision Audio and Innovision Display Systems Version 2021.04 US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Template Effective Date: 27 MAY 2019 | HOOD05162003010284 Job Aid Effective Date: 14 SEP 2021| HOOD05612003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table of Contents Introduction 3 Innovision Overview 5 SIEMENS Healthineers Common Hazards 12 Labelling 13 Innovision System Components 14 Functional Indicators 21 Table Adapters Installation 23 Patient Display Installation and Battery Tips 29 Hints 33 US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Patient Examination Workflow Quick Guide – SIEMENS Healthineers Introduction: Compatible MR Systems MAGNETOM Family – Innovision Audio and Innovision Display Systems SIEMENS Healthineers The Innovision Audio and Innovision Display systems are safe for use and compatible with the following Siemens Healthineers MR systems: MAGNETOM Lumina • MAGNETOM Altea • MAGNETOM Lumina • MAGNETOM Vida • MAGNETOM Sola US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Introduction All safety information in the valid operator manuals must be adhered to without fail. Components of the Innovision Audio and Innovision Display systems are located both in the examination room and the control room. It is important to pay attention to the intended location of each component as some components are not MR Safe and must not be taken into the examination room (including the MR system) under any circumstances. The safety, MR compatibility, efficacy and electromagnetic emissions of the Innovision Audio and Innovision Display systems cannot be guaranteed should the system be modified, operated with non-Innovere components or used in a way other than specified in this operator manual. Use of the Innovision Audio or Innovision Display system with patients who have metallic implants is not permitted. According to EU regulation 2017/745 (MDR), any serious incident that has occurred in relation to the device must be reported to the manufacturer and the competent authority of the EU Member State in which the user and/or patient is established. Metal Disclaimer - The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously Effective Date: 14 Sep 2021| HOOD05162003222253 mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the Unrestricted © Siemens Healthineers, 2021 responsibility of the implant manufacturer, not of Siemens. Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview The components of the Innovision system are placed in the control and in the examination room. Connections between the components in the control room and the components in the examination room are wireless. Overview Control Room (2) (1) Console Unit and Battery Charger (2) Audio and Video Bridges (control room) (1) i The position of the Audio and Video Bridges may vary, to serve special customer needs. Individual placement is based on Service Engineer’s installation recommendation. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview Overview Examination Room (3) Audio and Video Bridges (examination room) (3) SUMENS (4) Personalized Patient Display (PPD) and Pillow 4 i The position of the Audio and Video Bridges may vary, to serve special customer needs. Individual placement is based on Service Engineer’s installation recommendation. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview The Innovision system is an infotainment system designed to improve patient experience during an MRI exam. The Innovision system consists of two main components: • Innovision Audio infotainment system • Innovision Display Innovision Audio comes with a specially designed pillow and earplugs to reduce MRI noise while delivering clear sound through conduction hearing. Innovision Display is compatible with Innovision Audio. Innovision Display provides an immersive display that creates the illusion of an enlarged bore. Innovision Display enables the display of a countdown timer to help patients keep track of time. The components of the Innovision system are placed in the control and in the examination room. Connections between the components in the control room and the components in the examination room are wireless. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview Technologist Console You have everything under control with the dedicated technologist console. The console unit is the control center of the Innovision system. The console unit is used for the following: • Select and/or change the entertainment • Control the volume of the entertainment • Determine the wireless and battery status of the Innovision Audio system • Set the count-down timer for the patient (when connected to the Innovision Display system) The connection status of the audio bridge (examination room) and the pillows is shown on the base of the console unit. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview Patient Display Engage your patient even before the table moves into the bore with the unique patient display. The special design provides a comfortable viewing experience. In addition to a video, patients can see a display informing them about the remaining scan time – which can have a comforting effect. Moreover, the display seems to be as far away as the top of a 90 cm bore – making the inside of the bore feel virtually larger. This is an added advantage for all patients, including those who are anxious or claustrophobic. The patient display is wireless and powered by Innovision rechargeable batteries that last for over four hours of continuous operation. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview Comfort Pillows and Pillow covers The Innovision solution includes two unique comfort pillows. Both the standard pillow and the head/neck coil pillow are made of comfortable memory foam. Their ergonomic design increases patient comfort during scanning. The pillows are also easy to clean. Their coating is medical grade, sterilizable, and anti-bacterial. In conjunction with ear plugs, ambient noise can be reduced by at least 33 dB, while patients can clearly hear the audio signal from the entertainment system and the voice of the technologist. The pillows are wireless and easy to handle. They operate on internal batteries that last for over 12 hours of continuous operation. The pillows can be recharged via a cable connection to the Innovision battery charging station. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision Overview Comfort Pillows and Pillow covers The universal pillow covers are compatible with both the standard pillow and the head coil pillow. The pillow covers act as an additional level of sanitary control to put patients' minds at ease and reduce the frequency of pillow cleaning between patients. The pillow covers are made of a non-woven polypropylene fabric that is biocompatible and disposable. The pillow covers are intended for single use only. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Common Hazards During software updates malfunctions of the system may occur. Update the console unit software only while the system is not in use with a patient. System components marked with MR Unsafe may contain metal or ferromagnetic components that can get pulled into the magnet! Injury to the patient or personnel Property damage may occur. Ensure that system components marked with MR Unsafe do never enter the examination room including the MR system! The audio bridge (examination room), video bridge (examination room), personalized patient display (PPD), pillows or the battery with MR systems must not be used with other than 1.5 T or 3T! These components are MR Conditional! Metal Disclaimer - The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously Effective Date: 14 Sep 2021| HOOD05162003222253 mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the Unrestricted © Siemens Healthineers, 2021 responsibility of the implant manufacturer, not of Siemens. Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Labelling MR Safe MR Conditional MR Unsafe MR MR MR MR MR MR • Table adapter Set • PPD • Console Unit • Innovision Earplugs • Batteries • Battery Charger • MR Safe Glasses • Standard Pillow • Video Bridge (control room) • Pillow Covers • Head Coil Pillow • Audio Bridge (control room) • Head coil Foam Spacers • Video Bridge (exam room) • Intercom interface box • Audio Bridge • Storage Cart The Innovision symbol is located on patient tables that are installed with a height limiter. The Innovision Innovision system must only be operated with patient tables labeled with this symbol. Metal Disclaimer - The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously Effective Date: 14 Sep 2021| HOOD05162003222253 mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the Unrestricted © Siemens Healthineers, 2021 responsibility of the implant manufacturer, not of Siemens. Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components (1) Entertainment Auxiliary Out (2) Power Port 2 (P2) IVK (3) Optional: Entertainment Video Out (4) Intercom Auxiliary Out 1 2 3 (5) Entertainment Auxiliary In (6) Power Port 3 (P3) SIEMENS Healthineers - 4 5 6 Console Unit front view with Console Unit rear-view iPad mini with touchscreen iPad mini with touchscreen and entertainment volume knob US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Table adapter set (1) Pair of head-side table adapters (for head-first patient positions) (2) Single foot-side table adapter (for feet-first patient positions) Hint: Keep the adapters mounted on the table / For patient position-change, just move the Personalized Patient Display (PPD) (3) Lever to Lock/Unlock Positions (3) (2) (1) US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Audio and Video Bridges – pairwise mounted (control room/examination room) Audio Bridge Video Bridge • Audio Bridge in the examination room to be used with • Video Bridge in the examination room to be used with one Innovision battery pack two Innovision battery packs • Audio Bridge in the examination room has up to 24h • Video Bridge in the examination room has up to 6h operation time (7h recharging time) operation time (7h recharging time) (3) (3) SIEMENS SIEMENS .. Healthineers Healthineers SIEMENS .. Healthineers SIEMENS .... Healthineers (2) (2) MR MR MR MR (1) (1) (1) Power Button (1) Power Button (2) LED Control Lights (2) LED Control Lights (3) Innovision battery (battery packs to be inserted in the (3) Innovision battery (battery packs to be inserted in the devices, examination room) devices, examination room) US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Pillows Two different Pillows can be used: (1) Standard Pillow: The standard pillow is used for any examination for which head and/or neck imaging is not required. (2) Head Coil Pillow: The head coil pillow is used for examinations for which a head or head/neck coil is required. (1) (2) The pillows provide audio to the patient during their MR examination. The pillows are powered by an internal 3.7 V, 3.2 Ah lithium polymer battery. The battery capacity may be reduced after 3–5 years of use. The operation time of the standard and head coil pillow - internal battery is up to 24h, recharging time (empty to full) is 4h each. Metal Disclaimer - The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously Effective Date: 14 Sep 2021| HOOD05162003222253 mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the Unrestricted © Siemens Healthineers, 2021 responsibility of the implant manufacturer, not of Siemens. Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Personalized patient display (PPD) (1) (2) The personalized patient display (PPD) provides visual entertainment to the patient during their MR examination. The PPD non-permanently mounts to the patient (4) (3) table of the MR system via a set of table adapters provided with your Innovision Display system. (1) Mirror with screen behind it (2) Battery compartment Patient Display in the examination room to be (3) Power button and LED control lights used with two Innovision battery packs. (4) Table adapters that fit into the MR table rail Patient Display in the examination room has up to 6h operation time (7h recharging time). US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Earplugs The earplugs provide > 33 dB of noise attenuation when used correctly. The earplugs are intended for single use only . Innovision innovere wir w MRl experience US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Innovision System Components Batteries The Innovision system includes ten batteries. One battery is needed to power Innovision Audio. Four batteries are needed to power Innovision Display. Observe the operator manual regarding the Indicator lights. Be sure to check the battery status during the day to ensure that the batteries are replaced when there is a low battery indication. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Functional Indicators Battery charger The battery charger can charge up to five batteries, the standard pillow and the head coil pillow simultaneously. Charging times are outlined in the table below. System Component Operation time Charging time (empty to full) Standard and Head Coil Pillow – internal battery 24 hours 4 hours Audio Bridge (examination room) – 1 Innovision 24 hours 7 hours battery Video Bridge (examination room) – 2 Innovision 6 hours 7 hours batteries Personalized Patient Display – 2 Innovision 6 hours 7 hours batteries US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Functional Indicators Battery Charger Indicators Indicator Lights The following indicator lights are shown on several components: Color Meaning Symbol Color Meaning Symbol Color Meaning No color No battery inserted No color Off No color Not connected to power source Solid white Battery is charging Blinking blue On, but not connected Solid green Connected to power source Solid green Charging is complete and on Solid blue On and connected No color Battery life > 1 hour Solid yellow Battery life < 1 hour Solid green Pillow is plugged in, charg- ing is complete Solid white Pillow is charging US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the table adapters The PPD is mounted on the patient table with the help of the table adapters. • Ensure that the table adapters are installed correctly x ´ Location of the table adapters (1) Table adapters at the head end of the table (for headfirst patient positions) (2) Table adapter at the foot end of the table (for feet first patient positions) hineers - SIEMENS (1) US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 N - Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the Table Adapters at the Head End The table adapters for the head end of the patient table are labeled for the left (marked “L”) and right (marked “R”) side of the table, respectively (when facing the magnet cover). The procedure for installing the left and right adapter is similar. Left Right US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the Table Adapters at the Head End (1) Rotate the table anchor into (2) Position the table anchor near the (3) Press the release button on the groove on the side of the patient end of the magnet-side of the table adapter to open the lever. table. The anchor should be rolled patient table. Sometimes the lever does not go in towards the center line of the all the way itself and you have to patient table. push a bit with your finger. This is due to the tolerance of the slot in the table. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the Table Adapters at the Head End (4) Place the table adapter onto the table anchor. (5) Position the table adapter such that aligns with the end of the patient table. O When the patient table is below the home position the end of the table adapter can positioned as close to the MRI as possible before being locked in place. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the Table Adapters at the Head End Close the lever. The right table adapter is installed. (6) Install the left table adapter in the same way. (7) To remove a table adapter, press the release button on the top of the table adapter. The table adapter can then be lifted from the patient table. The table anchor can be left in the patient table or removed and attached to the table adapter for storage. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Table Adapters Installation Installing the Table Adapters at the Foot End The position of the table adapter for feet first patient positions may vary. Therefore, you can slide this table adapter along the rails of the patient table. 1) Place the table anchors into the grooves on the side of the foot end of patient table as performed for the head-side. 2) Position the table adapter with the concave part of the “U” towards the magnet cover and place onto the table anchors. 3) Close the lever. 4) Slide the table adapter to desired location. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Patient Display Installation and Battery Tips Installing the Personalized Patient Display (PPD) Please, always carry the PPD by the side handles. The personalized patient display (PPD) is mounted on the patient table with the help of the table adapters, make sure the table adapters are installed (head end or feet end). 1) Lower the patient table by approximately 30 cm. 2) Attach the PPD to the table adapters. Place the feet of the PPD into the adapter slots at an angle such that the toe of the PPD catches the lip of the adapter. • Then allow the PPD to tilt back into its installed position, such that it is securely in place. • No lever or lock mechanism is required to securely mount the PPD in the table adapters. To remove the PPD from the table adapters perform the opposite motion and tilt the PPD by ap-proximately 45 degrees forward. At this point the PPD can be removed from the table adapters. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Patient Display Installation and Battery Tips System Operation v Innovision Use the PPD only on a patient table that has a height limit installed. Installed height limit is labeled on the table with the “Innovision” symbol. Ensure that the table adapters are installed correctly. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Patient Display Installation and Battery Tips Charging batteries and pillows Before using the Innovision system be sure to charge the To charge the pillows, connect the standard pillow and/or the batteries and the pillows with the battery charger. head coil pillow to battery charger via USB charging cable. (1) When you see the low battery indication on a single (3) battery, whole pairs of batteries should be changed for (2) fully charged ones. O (4) To charge the batteries, put the empty batteries into the (1) Battery charger slots of the battery charger. (2) USB charging cables (3) Standard pillow The indicator lights turn solid white if the batteries are (4) Head coil pillow inserted correctly and are being charged. The indicator lights turn solid white if the pillows are connected If indicator lights are solid green, then the batteries are correctly and are being charged. fully charged. If indicator lights are solid green, then the pillows are fully charged. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Patient Examination Workflow Quick Guide – SIEMENS Healthineers Patient Display Installation and Battery Tips Reminder on How to Change Batteries of the PPD 1. 1 2. 3. 1) Collect two charged batteries from the battery charger. 2) Lower the patient table of the MR system so you can easily access the battery compartment at the top of the PPD. 3) Lift the battery lever to unlatch the lid of the battery compartment. 4) Remove the battery compartment lid while the lever is lifted. Ensure that the battery compartment on the PPD is sealed to 5) Pull back the battery clip and insert a battery into a slot - avoid Loss in Image Quality. one battery at a time. 6) Place the lid back on the PPD. 7) Close the battery lever. When the lever is released, the lid will latch. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Hints Starting up and shutting down the Innovision system Follow the installation and operation instructions. Observe the Operator Manual and make yourself familiar with all safety related items and the terms of use of the equipment. Simultaneous powering of two pillows may disrupt the audio communication. Do not power on a pillow while another pillow is already in use. Risk of tissue heating and burns when using the MR Conditional pillow with transmit-receive head coils! Do not use the pillow with transmit-receive head coils. Use the head coil pillow only with 20-channel, 32-channel and 64-channel head and neck coils. Loss of MR image quality when using the head coil pillow for applications other than head and neck applications. Use the head coil pillow only for head and neck applications. US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 Innovision Audio and Innovision Display Systems – SIEMENS Healthineers Hints Starting up and shutting down the Innovision system Use the PPD only on a patient table that has a height limit installed. Do not put your hands or fingers on the mirror while stowing the arch! Do not place hand or fingers on the mirror arch during the process of arch stowing. Unmount the PPD before undocking and moving the dockable patient table of the MR system to prevent injury to the patient or property damage. Charge the battery only with the battery charger that was supplied with your Innovision system. Use the battery only during its specified lifetime. Avoid damage, overheating, and contact with fluids. Do not crush, submerge, or open batteries. Only use the batteries if the enclosure is intact, undamaged and dry. Interaction with other equipment Only use the Innovison system in the configuration suggested in the operator manual! US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com US Job Aid Effective Date: November 15, 2021| HOOD05162003234019 Effective Date: 14 Sep 2021| HOOD05162003222253 Unrestricted © Siemens Healthineers, 2021
- MR
- Innovision
- Audio
- Display
- Components
- Installation
- Patient
- table
- adapters