MAMMOMAT Inspiration VB60 or Higher: How to Perform Magnification Views
MAMMOMAT Inspiration VB60 or Higher: How to Perform Magnification Views step by step
How to Perform Magnification Views MAMMOMAT Inspiration VB60 or Higher; Women's Health 1. Register your patient 2. Go to the icon gallery to modify the Icon to a Mag Icon. Be sure to select the appropriate Magnification Acquisition mode from the dropdown. Modified Views Please select the view position and modifier(s) Acquisition mode Prime Standard 2D Spot Implant Axillary Teil Cleavage Prime Magnification Rolled Inferior Rolled Lateral Spécimen Tomo Magnification 2D+Tomo Prime+Tomo L-ML L-XCC Tomo Implant 2D+Tomo Implant L-MLO L-XCCL R-XCCL R-MLO L-LM L-XCCM R-XCCM R-LM L-LMO R-LMO L-CC R-CC L-FB R-FB L-SIO R-SIO 3. Magnification view will appear with a magnification glass. Images cc ml 4. The Acquisition mode in the Acquisition tab will automatically default to MAGNIFICATION, with the correct IPPG. Acquisition Acquisition mode: Magnification IPPG: F2_Mag SIEMENS siemens.com/healthineers Healthineers Job Aid |How to Perform Magnification Views Effective Date: 5/17/2017 | Quality HOOD05162002602649 5. If you forget to attach the Magnification stand OR forget to select the appropriate Acquistion mode, the message below will appear. WH AWS X Current table is not suitable for acquiring the next selected image type. Please mount the appropriate table. OK 6. Perform Mag views. Siemens Healthineers Services Page 2 of 3 Job Aid |How to Perform Magnification Views Effective Date: 5/17/2017 | Quality HOOD05162002602649 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- MAMMOMAT Inspiration VB60 or Higher: How to Perform Magnification Views