MR View&GO 3D MIP Numaris XA31
This Job Aid reviews workflow to post-process 3D image data using Maximum Intensity Projection (MIP).
MR View&GO – 3D MIP Job Aid syngo MR Systems with Numaris X The 3D Step provides 3D post-processing functions like MIP 1. Viewing Step of MR View&GO, select images for 3D post-processing 2. Favorite Tools area, select Show in 3D icon to load images into 3D Case Navigator Favorite Tools X 3D O Show in | TimeCurve ADC & b- Compose 3D value Combine 3. Select MIP Thin layout (If not previously selected) 3D ALF HRA View&GO Dataset Siemens_Healthineers View&GO Dataset Siemens_Healthineers 123456789 *1/28/1991, M, 30Y MAGNETOM Altea 123456789 *1/28/1991, M. 30Y MAGNETOM Altea CURRENT MR XA20 HFS CURRENT 6/14/2019 6/14/2019 MPRIMIP MPRIMIP MRA Brain_3DTOF 1, 2 MRA Brain_3DTOF MPR 2TP MPRIVRT MIP THIN Latest latest 2TP STUDY ID cd328ed3-1ea6-45 STUDY ID cd328ed3-1ea6-45 9:17:08 AM 9:17:08 AM 7 IMA ~1 FRM ~68 7 IMAn.a. FRM n.a. RAF RAF SL 0.5 1 cm SPC 0.5 0.5 SPC 0.5 1cm MIP THICK Reset F A TR 23.6 TR 23.6 Layout TE 4.9 TP O TE 4.9 BW 100.0 TP O MPR THICK : p2 MAGN/NORM/DIS2D SP H26.9 BW 100.0 SP P11.4 404*456s | MPR THICK : p2 MAGN/NORM/DIS2D 404-456s | A1/SAT1 Tra>Sag(1)>Cor(1) A1/8AT1 >Sag(2)>Tra(-1) HE1,3,4 321 "13dir / 20 128 HE1.3,4 321 *13dir / 20 128 HRA HRA View&GO Dataset Siemens_Healthineers View&GO Dataset Siemens_Healthineers 123456789 MAGNETOM Altea 123456789 "1/28/1991. M. 30Y "1/28/1991. M. 30Y MAGNETOM Altea CURRENT MR XA20 CURRENT MR XA20 6/14/2019 6/14/2019 HFS MRA Brain_3DTOF 1. 2 MRA Brain_30TOF latest latest STUDY ID cd328ed3-1ea6-45 9:17:08 AM STUDY ID cd328ed3-18:18-35 7 IMAn.a. FRM n.a ALF RAF SL 0.5 1cm SPC 0.5 SL L A TR 23.6 TR 23.6 TE 4.9 TP 0 TE 4.9 BW 100.0 TP O SP L1.0 BW 100.0 MPR THICK : p2 MAGN/NORM/DIS2D SP P11.4 404*456$ 1 MIP : p2 MAGN/NORM/DIS2D 404.456$ | A1/SAT1 Sag>Cor(-2)>Tra(-1) A1/SAT1 Cor>Sag(2)>Tra(-1) HE1,3,4 321 HE1,3,4 21 "113dir / 20 128 *13dir / 20 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 4. 3D Case Navigator, select Punch Tool icon Double-click MIP image, so it loads into a one-by-one segment 3D X MPRIMIP MPRIMIP MPR 2TP MPRIVRT MIP THIN 2TP MIP THICK Reset Layout Parallel Radia Radial Curved Ranoes Ranges Slice ... Ranges & Punch Clip Box Lock Ref. Lines 5. Punch Tool (Only available for MIP image) Deselect Auto (Default = On) Select Remove Outside or Remove Inside based on intended action Remove Inside Remove Outside Undo Redo Auto Punch Reset 6. Left-Click and draw around anatomy Double-click to close drawing loop Note: If your drawing needs to be adjusted, right-click on drawing loop and select the nudge tool Correction Pen Nudge Tool Delete Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 2 of 7 Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 7. Select Punch to Apply Remove Inside Remove Outside Undo Redo Auto Punch Reset 8. Repeat Draw Punch Tool Steps to remove additional areas in other orientations Note: Change Orientation, ‘right-click’ on Orientation Cube and select Orientation (or) Depress right-mouse button on MIP Image and drag to new orientation Ortho Sync F (feet-head) TP 0 A (anterior-posterior) L (left-right) 456s | Sag H (head-feet) 321 128 P (posterior-anterior) R (right-left) Reset position in all segments Turn Off Punch Tool, select ‘Esc’ Key on computer keyboard (or) reselect Punch Tool Icon from 3D Case Navigator to turn off tool 9. 3D Case Navigator, select Radial Ranges 3D × MPRIMIP MPRIMIP MPR 2TP MPRIVRT MIP THIN 2TP MIP THICK Reset Layout Parallel Radial Radial Curved Ranges Ranges Slice ... Ranges Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 3 of 7 Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 10. 3D Sequence opens in Ranges Tool View&GO Dataset Siemens_Healthineers View&GO Dataset Siemens_Healthineers View&GO Dataset Siemens_Healthinger 123456789 MAGNETOM Altea 123456789 MAGNETOM Altea 123456789 *1/28M1991, M. 30Y MAGNETOM Anea MIR XA20 *1/28/1 991, M, 30Y MR XA20 T1/28/1991. M. 30Y CURRENT CURRENT CURRENT 6/14/2019 2 6/14/2019 HES 1, 2 6/14/2019 MRA Brain_3DTOF MRA Drain_3DTOF MRA Brain_3DTOF latest latest latest STUDY ID cd328e03.0e STUDY ID co328ed3. STUDY ID cd32Bed3 1va€45 9:17:08 AM 9:17:08AM R 3 A 1 cm F TR 23.6 TR 23.6 TE 49 TE 4.9 TP O TE 4.9 EW 100.0 BW-100.0 MIP: p2 MAON/NORMIDIS2D MIP : p2 MAON/NORM/DIS2D SP H27.1 404"4565 1 MIP< 02 MAONINORMDIS2D Total Angkx 180.0 * 04-45691 MIJSAT1 A1/SAT1 HE1,3,4 Arcle Between mages: 100. HE1,3,4 "13d11 / 20 "13dir/ 20 ............... Parallel Radial Curved new&GO Dataset Preview 1/201 981, M. 30Y Siemens_Healthineer Preset|Select the Preset STUDY 1/28/2021 Angle between Images 10.0 Number of Images 19 Field of View 207.2 X 207.2 mm Presets Orientation Image series Long Axis Short Axi Frontal 5cm LAT Start Accept Close 11. Create Radial Ranges Define Orientation of Ranges (can use available presets or graphically adjust) Preset Select the Preset Presets Orientation Long Axis Short Axis Frontal Axis Define Parameters Angle between Images Number of Images Field of View Angle between Images 10.0 Number of Images 19 Field of View 207.2 - X 207.2₮ mm Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 4 of 7 Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 Adjust Slice Order if needed using Swap Order under Orientation tab Presets Orientation Image Series Ortho Set Axis Set Axis Swap Swap Normalize Rotate Ranges Vertical Horizontal Order View orientati ... Preview Select Start Start Accept Close 12. Label Range Series Name and select Accept to Create a New Series Note: Series Navigator displays an Icon indicating a New Series was created Note: If other orientations are needed, change orientation and repeat Parallel Radial Curved Preset Select the Preset Angle between Images 10.0 Number of Images 19 Field of View 207.2 207.2 - mm Presets Orientation mage Series Range Series Name MRA Head_Spin Image Comment Include Reference Image Reject Accept Close Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 5 of 7 Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 13. Creating a User Preset After setting up Radial Ranges Orientation and Parameters, select Create Preset Presets Orientation Image Series Long Axis Short Axis Frontal Create Axis Preset Label Preset Name and Range Series Name, and select OK to Save Create Range Preset ? X Preset Name MRA Head_Spin Range Series Name MRA Head_Spin AutoViews Anatomy Preset Details OK Cancel After Saving Preset, Ranges are now available under User Presets Preset Select the Preset Favorites User presets Ang MRA Head_Spin Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 6 of 7 Job Aid | MR View&GO – 3D MIP Effective Date: 07/29/2021 | HOOD05162003208196 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/29/2021 | HOOD05162003208196 Healthineers Page 7 of 7
- MR
- View&GO
- 3D
- MIP
- Numaris XA31
- numaris x
- maximum
- intensity
- projection
- postprocessing