MR syngo MapIt Numaris X
The MR syngo MapIt Numaris X Job Aid provides workflow to fuse Parametric Maps with an anatomical series.
MR syngo MapIt Fusion – Numaris X Job Aid MR syngo MapIt Fusion – Numaris X MR syngo MapIt – Numaris X Job Aid provides workflow to fuse Parametric Maps with an anatomi- cal series. In this workflow example, a T2 Star Map and Anatomical images were used. Important Note – Measuring data via ROIs can only be done on non-fused raw data series (Mean Value = ms) 1. Acquire MapIt and matching Anatomical series 2. Open Patient Browser a. Select Patient in Results List -or- Select Anatomical and MapIt series in the Series List (Ctrl + Left Click) Results (70 results, 4:57:43 PM) Series Patient Name Patient ID Date of Birth Study Date a ... | Study Descripti ... | Accession Nu ... Workflow Study Archived Corrected map it O 1 4 11/24/2020 1 ... knee^library MR Basic T1Map_anatomical_F T1Map_anatomical_F 1_Images_B1cor 12Map_anato Aerd Abdomen ramology_cid ... Aera Abdomen Germany_MAC 8/1/1966 8/13/2020 9: ... Cirrhosis Asci ... XA30A Aera Neck Austria MAC 3/1/1955 8/11/2020 2: ... CE Dixon SM ... XA30A Aera Knee Germany_MAC 8/11/2020 8/11/2020 12 ... Meniscal tear ... XA30A Aera_Heart Germany_MAC 8/5/2020 8/4/2020 9:5 ... Pathology_He .. XA30A Aera Knee Germany_MAC 7/31/2020 7/31/2020 11 ... Obese CE_S ... XA30A R2_Images 12StarMap_ anatomic T2Star_Images R2StarMap_an Prisma Head Germany_MAC 7/24/1967 7/24/2020 12 ... Tumor_3D_2 ... XA30A Prisma_C-spine Germany_MAC 2/5/1947 7/22/2020 11 ... Degenerative ... XA30A b. Right Click on Study or Selected Series > select MR Basic Workflow Open with Favorites View as Read-Only with Suggested Batch Open MR Basic Acrian MMardflem Viewing 3. MR Basic Private Layouts a. Left Click Layout Icon Public Layouts b. Select Stack 1x1 c. Select Close Stack 1x1 Stack 2x2 Stack 3x3 Stripe 2x2 Stripe 3x3 Stripe 4x4 Dynamics Compare 2x2 >>> Advanced Close Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 4. MR Basic > Layout 1x1 SIEMENS O ₲ 2011974MO X Healthineers MR Basic HLP Series MR Basic Reading map it Hospital 0 ^1/1/1974, M. 46Y Skyra Single MR E11 CURRENT FFS 11/24/2020 +LPH Viewing [2_me3d_we_sag_p2_iso Private Layouts latest STUDY ID 3 Public Layouts 1:54:13 PM 22 IMA 103 Stripe 33 Stipe 4x4 ARH >> Advanced Close Findings Navigator Name Value Source 0.6 TR 39.0 Tools TE 17.0 TP O TA 06:32 SP R55.7 BW 160.0 FOV 141*150 p2 M/ND/NORM 226p*256 Synch Lack Sag>Cor(21)>Tra(6) Naslgati A1/PFP/SAT1/WE Zoom 3.82 K15 W 409 Export "me3d1r3 / 8 173 MEDIC 5. Series Navigator a. Select MapIt Images (1st) > Depress Left mouse > Drag and Drop into Segment b. Note – if anatomical images are placed in segment 1st, punch tool doesn’t work as indicated. Series map it Hospital *1/1/1974, M. 46Y Skyra - Series Name MR E11 CURRENT FFS Current 11/24/2020 +LPH T2Star_Images MR. 11/24/2020 knee^library latest AKnee_Scout_15ch STUDY ID 3 1:44:22 PM TIMap_anatomical_FLIP1.01 18 IMA 2 T1Map anatomical_FLIP2:01 T1_Images . BIMap_for_TI_mapping_ana > BIMap_for_11_mapping_FA 10 11Map_anatomical_FUIP1.late 11 T1Map_anatomical_FLIP2.late 12 T1_Images_B1corr ARH 13 . 12Map_anatomical 14 T2_Images Tom 15 . R2Map_anatomical 18 T2Star Images R2StarMap_anatomical 3.0 20 R2Star_Images 21 12 de3d we sag_p2_iso 22 12_me3d_we_sag_p2_iso TR 445.0 TE 4.4 TP O TA 02:50 SP R59.1 23 12_fi3d_sag_p2_iso FoV 160'160 24 12 trufijd we sag_p2_iso BW 260.0 T2º MAP/ND 384"384 Sag>Cor(21)>Tra(6) Zoom 2.55 K15 100 *#1245 / 60 50 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 2 of 7 Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 c. Select Anatomical Images (2nd) > Depress Right mouse > Drag and Drop into Seg- ment i. Select Fuse MPR/MPR ii. Note – Use matching anatomical series with lowest TE (recommended), or a different anatomical series with similar frame of reference (3D Recom- mended) 14 T2_Images 15 + R2Map_anatomical Replace 16 R2_Images Insert before 17 + T2StarMap_anatomical Fuse (MPR/MPR) Echo_01 [TE=4.36] Echo_02 [TE=11.9] Replace all Series 5cm Echo_03 [TE=19.44] Echo_04 [TE=26.98] 6. MR Fused MPR/MPR a. Lower Right Corner Menu > Rainbow Left Mouse Click D Red b. Select Color LUT1 > Rainbow Spectrum Correction Tools % Spectrum 10 Step ImageFilter Smooth Grays Analysis Tools map it x - "1/1/19/4. M. 45Y Ekyra CURRENT | CURRENT ASIST Perfusion Auto Windowing STUDY 11/24/2020 Avuto T2Ster_Images | T28terva> a atoTica atest latestEcho 0 invert O MR Color LUT 1 11/24/2020 | 11:24/2020 1 44 71 PM | 1 24 71 PM 8 IMA -6 | 17 IMA -8 100 MR Color LUT 2 5 CMR Presets 1 ng ARM EPR FUSION MR Presets 2 Reset Windowing D- Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 3 of 7 Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 7. MR Fused MPR/MPR Grayscale a. Lower Right Corner Menu > Perfusion Left Mouse Click Heart b. Select Color LUT2 > Grayscale Hot Iron K HLP Hot Metal New map it Hoep ta *1/1/1974. M. 45Y Parathyroid CURRENT | CURRENT STUDY 11/24/2020 T2Star_Images | T2Startviap. aoatomica latest | latest Echo_01-3 Rainbow 1.24-2022 /24.2020 5cm IS IMA -6 | 17 IMA - Red Correction Tools% Spectrum ImageFilter Smooth ARH Spectrum 10 Step Analysis Tools x - MPR FUISION SL SPC 0.4 Grays Auto Windowing auto ASIST Perfusion MR Color LUT 1 invert O MR Color LUT 2 2 a 50 00% MR Presets 1 384*384 1207 AC 1 MR Presets 2 Reset Windowing 8. Punch Tool (Optional) Zoom/Pan a. Upper Left Corner Menu > K select Punch 3D Reference Point K b. Select Remove Outside Rotate c. Deselect Auto Windowing Y Il Movie CURRENT 24/2020 Home Position, 12StarMap a Region Growing Scroll 11/24/2020 1 PMv Remove Inside Automatic Registration Remove Outside Auto Punch Reset Punch Ranges Save as Series Fit to Segment Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 4 of 7 Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 9. Depress Left Mouse > Draw around Area of inter- est as needed a. Select Punch Icon b. Note – Can change between Remove Inside and Remove Outside as necessary Remove Inside . Remove Outside Auto Punch c. Punched Image i. Select Esc on keyboard (e.g., cancels Punch Mode) HLP map it Hospital +1/1/1974, M. 46Y Skyra CURRENT | CURRENT STUDY 11/24/2020 T2Star_Images | T2StarMap_anatomical latest | latest/Echo_01 11/24/2020 | 11/24/2020 1:44:21 PM | 1:44:21 PM 18 IMA ~6 | 17 IMA ~6 ARH Manip MPR FUSION SL min SPC 0.4 5cm 50.00% 384 384 AC 1 T2: Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 5 of 7 Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 10. Saving Fused Series Zoom/Pan a. Upper Left Corner Menu > Select Save As Series 3D Reference Point b. Save As Series window Rotate • Enter Series Name • Enter Image Comment Windowing Y • Select Accept Ell Movie CURRENT 124/2020 Home Position + des 12StarMap_anat Region Grolling 1 Scroll 11/24/2020 4:44:21 PM Automatic |Registration Save as Series X Punch Ranges Series Name Sag T2star Maplt Fused Save as Series Image Comment Right Knee Fit to Segment Accept Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 6 of 7 Job Aid | MR syngo MapIt – Numaris X Effective Date: 10/07/2021| HOOD05162003223004 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 10/07/2021 | HOOD05162003223004 Healthineers Page 7 of 7
- MR
- Parametric
- Maps
- Fusion
- Numaris X
- syngo
- MapIt