MR Tim Planning Suite (Set-n-Go) - Eline
This Job Aid reviews Tim Planning Suite (Set-n-Go) workflow for multi-slice measurements with multiple table moves.
MR Tim Planning Suite with Set-n-Go – Eline Job Aid Tim Planning Suite with Set-n-Go – Eline This Job Aid will review workflow to facilitate planning and evaluating multi-slice measurements, group the individual measurements or combine examinations with multiple table moves using Tim Planning Suite (Set-n-Go). Prerequisites for Set-n-Go Protocols • Distortion Correction – On (Default) o Automatically set to 2D Distortion Correction • (e.g., Resolution > Filter Image Parameter Card) • Inline Composing – only available if Distortion Correction Selected • Positioning Mode – ISO Mode must be selected o (e.g., System > Miscellaneous Parameter Card) • Sagittal and Coronal Slices o Hints – Required for Composing to work • Angle – Don’t angle ±1° • Overlap – Minimum of 50 mm required Dot Cockpit – Create a Set-n-Go Protocol (e.g., Whole Spine) 1. Open Dot Cockpit Icon 2. Select Whole Spine Protocol a. Program Editor > Edit b. Open Localizer, T1, T2 Sequence Dot Cockpit - Explorer ? X EXPLORER PROGRAM EDITOR Browse Import Export SIEMENS SIEMENS >> whole-spine >> clinical libraries »> set-n-go Edit localizer_I-III 00:51 head t2 tse_sag 11:58 › c-spine t-spine I-spine t1_tse_sag 12:39 whole-spine clinical libraries general lesion inline_composer set-n-go TimCT whole-spine neck soft tissue thorax Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 | HOOD05162003196026 Healthineers Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 c. Select Geometry > Tim Planning Suite Parameter Card i. Checkbox Set-n-Go Protocol – Implements Set-n-Go ii. Select Inline Composing iii. Composing Function • Select Spine (e.g., Spine, Angio, Adaptive, Diffusion) iv. Step – add number of table moves (steps) needed • Select [+] – adds Step to End of List • Select [-] – removes Step • Note: Repeat for Steps for each sequence in protocol (e.g., T1, T2, etc.) Routine Contrast Resolution Geometry System Physio Inline Sequence Common Saturation Navigator Tim Planning Suite Tim CT Set-n-Go Protocol Step 2 Table position F 501 : mm Table position memory Inline Composing Normalize None Composing Function Spine d. Select Resolution > Filter Image Parameter Card i. Checkbox Distortion Correction > Mode > Select 2D Routine Contrast Resolution Geometry System Physio Inline Sequence Common iPAT Filter Image Filter Rawdata Image Filter v Prescan Normalize ... ! Intensity Medium Unfiltered images Edge Enhancement Normalize Smoothing Unfiltered images B1 filter Distortion Corr. V Mode 2D Unfiltered images Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 2 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 3. Select Save Program Icon – when finished Whole Spine Set-n-Go Protocol Dot Cockpit - Program Editor (Program Path = USER Tree/Whole Spine/Whole Spine Set-n-Go .. ? X EXPLORER PROGRAM EDITOR Edit Simulate Standard USER Tree Save program : >> Whole Spine Set-n-Go >> set-n-go x Browse Search Default localizer I-III 00:51 USER t2 tse_sag 15:37 Q 11_tse_sag 12:39 sweet select a program or library Strategy Decision Interaction Pause Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 3 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 Exam UI – Tim Planning Suite Set-n-Go Workflow (e.g., Whole Spine) 1. Exam Task Card Tim Planning Suite ... a. Main Menu > select View > Tim Planning UI 21.05.11-21:53:23-D 10 IN-F2 / 2 HEZ 2. Run Localizers 5/11/2021 Un a. Localizers – All FoV Positions & Slices Shown in UI b. Composed Images created after all Set-n-Go localiz- HE3 HE4 ers are acquired ACS Protocol Evaluation NE1 NE2 View Image Tools 2 Segments 3 Segments Maestro UI SP1 Cardio LIL Tim Planning UI 10 cm Spine Planning UI Image Text On SP2 Reference Lines On Protocol Table Position On Coil Positions On [2] Adjust Volume On SP3 Graphics p3 CPR*/NORM/DIS3D/COMP_SP SP P37.7 CSI Matrix _AASpine_Scout_COMP_SA_1. FoV 600-400 Cor 3. T1 & T2 Sequences a. Composed Coronal/Sagittal – All FoV Positions and Slices Shown in UI • Yellow Box – active measurement step • Purple Box – additional measurement Tim Planning Suite Tim Planning Suite Tim Planning Suite 21.05.11-21:53:23-DST-1.3.12.2. 21.05.11-21:53:23-DST-1.3.12.HE1 11 IMA 9 /15 11 IMA 9/ 15 10 IMA 1 /2 5/11/2021 5/11/2021 HE4. HE4 NE2 ACS ACS A SP1 ACS SP2 [2] Ocm p3 CPR/NORMW/DIS3D/COMP SP LO. 600 -163 O I_AASpine_Scout_COMP_SP_1 .. synthetic CPR image Saa SP2 [2] p3 MPR/NORM/DIS3D/COMP_$P SP L8.0 I_AASpine_Scout_COMP_SP Fo FoV 598*163 Sag [2] XXXX p3 MPR/NORM/DIS3D/COMP_SP + I AASpine @sout GOMPAOP 4 -.. - Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 4 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 b. Sagittal and Coronals Protocol View Image Tools E • Check Overlap, Alignment and Position Slices Add Slice(Slab) Group c. Overlap Add Sat • Protocol > Overlap – check amount of overlap Delete All Graphics • Minimum of 50 mm overlap recom- Add Subprotocol mended to compose images Perpendicular Ctrl+1 d. Align FoV Icon – aligns FoV & overlaps all steps in a Orthogonal Ctrl+2 set-n-go protocol > select OK Turn Group Shift to Image Plane Overlap X Shift to Segment Center Swap Phase Overlap 50 [mm] Reset Inplane Rotation Stack - Ctrl+3 00 Stack + Ctrl+4 OK Cancel Help Gap Filling - Ctrl+5 Gap Filling + Ctrl+6 FoV - Ctrl+7 Foy + Ctrl+8 Overlap Ctrl+9 Select Apply – Runs sequences Align Parallel e. Align FoV 4. Axial Sequences a. Position First Group of Axial Slices • Check Alignment and Position Slices b. Select Align Parallel Icon – aligns additional axial slice groups Overlap X Overlap 50 [mm] OK Cancel Help c. Select Apply – Runs sequences Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 5 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 5. Run Entire Whole-Spine Set-n-Go Protocols Tim Planning Test 5/12/1977 Dot a. Hint – Don’t remove the patient from A Append Insert the table until the protocol is saved Append Pause .. Ctrl+Insert 1.2 I_AASpine_Scout Rerun from here b. Right Mouse on Protocol > select Save as 2.1 t2_tse_sag_448_p2 Rerun from here with .. Cut Ctrl+X 2.2 12_tse_sag_448_p2 Copy Ctrl+C 3.1 t1_tirm_sag_dark-fluid_p2 Paste Ctrl+V Delete 3.2 t1_tirm_sag_dark-fluid_p2 Del Clear All Shift+Del 4 AutoAlign Verification Save as. Ctrl+S 5 t2-tra options View Properties ... Alt+Enter 6.1 12_tse_tra 6.2 [2_tse_tra 8 00:00 c. Save As Window • Select Tree • Select Region • Select Exam • Enter Program Name • Name – enter name of protocol (e.g., Whole Spine Set-n-Go) d. Select Save Save as ? X USER sweet t_spine Shoulder_DE_Routine I_spine Knee 2D hip_left_unilateral Head_DotEngine Head c_spine Breast abdomen ankle_head_coil elbow shoulder_basic wrist Whole Spine Whole Spine - Set-n-GO New directory Name |Whole Spine - Set-n-GO Save Cance Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 6 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 Tim Planning Suite Parameter Card 1. Geometry > Tim Planning Suite Parameter Card a. Set-n-Go Protocol – indicates if Set-n-Go protocol is selected/deselected b. Step – Indicates current step number in Set-n-Go protocol i. Select [+] to add a step to end of list ii. Select [-] to delete a current step c. Table position – table position where sequence is measured i. H – table moves in Head direction ii. F – table move in Feet Direction iii. Note: Zero point defined by initial table position of first measurement of a series block d. Inline Composing – combines all images from multiple table moves (steps) for an orien- tation or weighting into a complete image (e.g., C, T, and L spine combined) e. Normalize – Off (Default) – reduces image intensity variation for whole body diffusion measurements (e.g., used for composed whole body diffusion) f. Composing Function – select an option i. Spine – based on Bone Structure, for Composing Spine Images ii. Angio – based on Vessel Structure, for an Overview of Vessels iii. Adaptive – based on elastic matching, to correct b0 induced inhomogeneities in image areas beyond magnetic homogeneity volume. (e.g., Abdomen, Long Bones) iv. Diffusion – correct phase encoding direction shifts caused by different adjust- ment parameters of steps of a set-n-go protocol (e.g., Axial Whole-Body Diffu- sion) Routine Contrast Resolution Geometry System Physio Inline Sequence Common Saturation Navigator Tim Planning Suite Tim CT Set-n-Go Protocol Step Table position F 501 - mm Table position memory Inline Composing Normalize None Composing Function Spine Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 7 of 8 Job Aid | MR Tim Planning Suite with Set-n-Go - Eline Effective Date: 06/08/2021| HOOD05162003196026 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/08/2021 |HOOD05162003196026 Healthineers Page 8 of 8
- MR
- Tim
- Planning
- Suite
- set-n-go
- eline