RAPIDLab® 1200 Series Blood Gas Systems Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
RAPIDLab® 1200 Series Blood Gas Systems Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks Hardware Overview Identify the differences between the four RAPIDLab 1200 systems Locate system hardware components Identify system consumables Locate the serial number Software Overview Log into the User Interface Identify Banner and Display area and functionality Identify the Main System screens and functionality Sample Processing Properly collect and handle samples Process a sample Enter patient sample data View, recall, and print patient results Calibration Describe what automatic calibrations are and when they occur Perform a manual calibration Identify failed calibrations Recall, print, and send patient results Quality Control Utilize the Required QC option Utilize the Automatic option Utilize the Unscheduled QC option Review results and identify QC failures Recall, print, and send QC results Daily/As Needed Maintenance Perform daily maintenance Perform as needed maintenance Periodic/Yearly Maintenance Perform periodic maintenance Perform yearly maintenance Troubleshooting Quality # HILS1921 Effective Date: 06/09/2017 Page 1 of 2 SIEMENS Healthineers siemens.com/healthineers RAPIDLab® 1200 Series Blood Gas Systems Competency Checklist Utilize the Diagnostics screen Remove obstructions from the sample Utilize the troubleshooting portion of Online Help Troubleshoot failed quality control and calibration Troubleshoot failed patient results Comments Areas of Improvement Next Steps Primary Operator Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: Quality # HILS1921 Effective Date: 06/09/2017 Page 2 of 2 SIEMENS Healthineers siemens.com/healthineers
- rapid
- lab
- competency
- training
- mentor
- checklist
- consolidated