syngo Calcium Scoring
syngo Calcium Scoring step by step
syngo® Calcium Scoring Computed Tomography 1. From the Patient Browser, load an appropriate Calcium Scoring data set into the Calcium Scoring application. ocal Database _ CASCORING 1 (LAD, CX, Thorax ECGTrigger! [2] ECGTrigger Scheduler CASCORING 2 (LAD, CX, R///// / DVD_R CASCORING 3 (LAD, RX, R///// / DVD_ROM CASCORING 4 (LAD) R///// / CASCORING 5 (LM, LAD. R///// / 2. Structures >130 HU in density will be highlighted pink. Scroll through the images to screen for densities in the coronary arteries. Pan, zoom and window as necessary. CASCORING 1 (LAD, CX. HOAG HEALTH CENTER 989235 Plus 4 Volume Zoom *01-Mar-1940, M, 59Y 17-Feb-2000 11:20:18.14 2 IMA 11 L 2.5/2.5 3. Enable the Pick Lesion icon to open the Artery Labels palette. Pick Lesion Artery Labels LM CX RCA V × SIEMENS siemens.com/healthineers Healthineers . Job Aid | syngo® Calcium Scoring Effective Date: 8/16/2016| Quality HOOD05162002591118 4. Scroll through the axial images in segment 1. Use the appropriate label in the Artery Labels palette to mark plaques in the coronary arteries. CASCORING 1 (LAD, CX, ... HOAG HEALTH CENTER 969235 "01-Mar-1940. M. 59Y PLUS4 VORM VASTA 17-Feb-2000 11:20 18:14 LM LAD RCA V X 5. Continue through the entire data set marking all lesions in the coronary arteries. Change labels in the Artery Labels palette as necessary. CASCORING 1 (LAD, CX. ... HOAGHEALTH CONTUR 989235 "01-Mar-1940. M. 59Y PLUS4 VON VASTA 17-Feb-2000 11:20:20 66 2MA 16 LM AD RCA V X 6. Calcium Scoring results will be displayed in segment 4. CASCORING 1 (LAD, CX, RCA) HOAG HEALTH CENTER -Of -Mw.1940. M. 59Y VAIA Threshold = 130 HU Artery Namber of Louiv. MASE Lezione Volume lima canal Calcium LM LAD 58.7 744 CX 0.0 OD RCA 2.4 3.9 Tots 70.2 (1) Lesion is volace based (2) Ers avaient Agreston score (3) lactropic interpolated volume (4) Calibration Factor: not avsincle Siemens Healthineers Services Page 2 of 4 Job Aid | syngo® Calcium Scoring Effective Date: 8/16/2016| Quality HOOD05162002591118 7. Right-click on an available filming placeholder to copy the active segment image to the report. Tools Report bu Copy Image Filming ............... ................. 8. Select the Report Wizard icon to enter additional patient information and to generate a report. Calcium Scoring Report Wizard X CASCORING 1 (LA Templates CASC Referring Physician Reading Physician Dr. Joe Smith XYZ Clinic Examination | Viewing XYZ City. XY 11111 History Tools Report Comment Filming M Patient Age: 59 years Include in printed report Image Report Wizard Patient Sex male Smoker 3D Total cholesterol level mg/dl yes no LDL-cholesterol loval mg/dl Diabetes Mellitus @ yes e no HDL-cholesterol level mg/dl Family history of myocardial events Triglyceride level mg/dl . yes @ no Blood pressure mmHg Left ventricular hypertrophy yes Simulation | CaScoring no · unknown Calculate Estimated 10-year risk Print OK Cancel Help Siemens Healthineers Services Page 3 of 4 Job Aid | syngo® Calcium Scoring Effective Date: 8/16/2016| Quality HOOD05162002591118 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4