syngo.via Advanced Configuration of Data Loaded with Boolean Expressions Job Aid
This job aid provides information about new features in the advanced configuration of data loaded which uses Boolean expressions and is available in syngo.via.
SIEMENS Healthineers MR Advanced Configuration of Data Loaded with Boolean Expressions Job Aid Template Effective Date: 27 May 2019 | HOOD05162003010284 Job Aid Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Advanced Configuration of Data Loaded with SIEMENS Healthineers Boolean Expressions - Table of Contents Overview 3 Configuration of data loaded ? X MR Configuration with Boolean Expressions 4 State Definition Alternative Configuration with Boolean Expressions 6 MR.11_sag.latest [Boolean Expression Alternative] MR Configuration with Boolean Expressions 10 [Boolean Expression Alternative] [Boolean Expression Alternative] Creating own Expressions 13 [Boolean Expression Alternative] + Current Alternative 3D OK Apply Save Cancel 2 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Overview SIEMENS Healthineers Challenges of the Configuration The series name of the scanned protocol defines which images are loaded into the segments. The series name for the same protocol type varies depending on the following factors: • System type • Software version CURRENT • Vendor From a reading perspective, the same protocol type or image type should be loaded into a certain segment, regardless of the series name. To help solve this challenge, an advanced Configuration of data loaded with Boolean Expressions can be used. In this job aid, we explain how to use this configuration. 3 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Configuration with Boolean Expressions SIEMENS Healthineers The advanced Configuration of data loaded with Boolean Expressions is ? X like a Google search to look for certain criteria within the series name. Configuration of data Loaded State Definition The search runs on the patient data that is currently loaded in the MR.t2_tse_tra.latest workflow. If the search term is found in the series name, the data will be [12][tse][tra][latest]::1 and 2 and 3 and 4 loaded into the segment. This configuration gives flexibility as the series name does not need to be + Boolean Expression 1: Current a 100% match. [MR][12][cor][latest]:: 1 && Configuration of data Loaded ? X Alternative t2_tse_tra_3mm_p2_s2 Istest State Definition MR.t2_tse_tra.latest [Boolean Expression Alternative] OK Apply Save Cancel To activate advanced mode in the Configuration + Shift and of data loaded, press the shift key and double- 7 - Current double-click click on the empty part next to the Current Alternative 3D button where the Boolean Expression information is shown. When the settings icon is OK Apply Save Cancel shown, the advanced mode is active. 4 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Configuration with Boolean Expressions SIEMENS Healthineers Advanced Mode When the advanced mode is Configuration of data loaded ? X Configuration of data Loaded ? × activated, the data to be loaded can be seen. State Definition State Definition MR.11_sag.latest MR.t1_sag.latest [Boolean Expression Alternative] [t1][sag][latest][post]::1 and 2 and 3 and !4 In normal mode, only [Boolean [Boolean Expression Alternative] [t1][sag][latest][se][f12d][tse][post]::1 and 2 and 3 and (4 or 5. [Boolean Expression Alternative] [t1][latest][mpr][post]::1 and 2 and 3 and !4 Expression Alternative] is shown [Boolean Expression Alternative] [t1][sag][latest][blade][post]:: 1 and 2 and 3 and 4 and !5 as text and the matching data that is loaded or found is + Boolean Expression 1: - Current - Current + [MR][t2][cor][latest]:: 1 && indicated in traffic light colors. Alternative Alternative 3D OK Apply Save Cancel OK Apply Save Cancel The examples in this job aid show the default configuration which is based Matching data is available and currently visible on the Siemens Healthineers scanner protocol naming and the different Dot Matching data is available, but not visible Engine strategies. No matching data is available Invalid data is configured 5 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Alternative Configuration with Boolean Expressions SIEMENS Healthineers Example 1 (1/2) Explanation of the expression in this dialog: Configuration of data Loaded ? X [t2][tse][tra][latest]::1 and 2 and 3 and 4 State Definition MR.t2 tse tra.latest [ ] The search term to be found within the [12][tse][tra][latest]::1 and 2 and 3 and 4 series name is within the square brackets. :: Separator between the terms and the command + Boolean Expression 1: - Current [MR][12][cor][latest]::1 && 1 and 2 and… The command for what to do with the terms Alternative OK Apply Save Cancel [t2][tse][tra][latest] :: 1 and 2 and 3 and 4 Terms What to do with the terms Separator between term and command 6 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Alternative Configuration with Boolean Expressions SIEMENS Healthineers Example 1 (2/2) [t2][tse][tra][latest]::1 and 2 and 3 and 4 Configuration of data Loaded ? X In this example State Definition MR.t2 tse tra.latest [12][tse][tra][latest]::1 and 2 and 3 and 4 - - C t2 = 1 tse = 2 tra = 3 latest = 4 + Boolean Expression 1: - Current [MR][12][cor][latest]::1 && Load the series with t2 and tse and tra and latest in the name. Alternative The term latest is normally not in the name, but is shown in the Series Navigator in the case of rescans. OK Apply Save Cancel If there are several matches, the most recent series is loaded. 7 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Alternative Configuration with Boolean Expressions SIEMENS Healthineers Example 2 [t1][sag][latest][post]::1 and 2 and 3 and !4 Configuration of data Loaded ? X In this example State Definition t1 MR.t1_sag.latest = 1 sag = 2 [t1][sag][latest][post]::1 and 2 and 3 and !4 [t1][sag][latest][se][f12d][tse][post]::1 and 2 and 3 and (4 or 5 latest = 3 [t1][latest][mpr][post]::1 and 2 and 3 and !4 post !4 [t1][sag][latest][blade][post]::1 and 2 and 3 and 4 and 15 = ! Exclamation mark excludes the series where this Boolean Expression 1: term is found. + Current [MR][12][cor][latest]::1 && Load the series with t1 and sag and latest, but not Alternative post in the name. If pre-contrast and post-contrast is added in the series name, the system will load the pre-contrast OK Apply Save Cancel but not the post-contrast series. 8 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Alternative Configuration with Boolean Expressions SIEMENS Healthineers Example 3 [t1][sag][latest][se][fl2d][tse][post]::1 and 2 and 3 and Configuration of data Loaded ? X (4 or 5 or 6) and !7 State Definition In this example MR.t1_sag.latest [t1][sag][latest][post]::1 and 2 and 3 and !4 [11][sag][latest][se][f12d][tse][post].: 1 and 2 and 3 and (4 or 5 t1 = 1 [11][latest] [mpr] [post]:: 1 and 2 and 3 and !4 sag = 2 [t1][sag][latest][blade][post]::1 and 2 and 3 and 4 and !5 latest = 3 se = 4 fl2d + Boolean Expression 1: = 5 Current [MR][t2][cor][latest]::1 & & tse = 6 post !7 Alternative = [sag][latest][se][f12d][tse][post]:: 1 and 2 and 3 and (4 or 5 or 6) and !7] Load the series with t1 and sag and latest, and either se or fl2d or tse, but not post in the name. OK Apply Save Cancel This is needed for the different protocols offered in a Dot Engine in different strategies. 9 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Configuration with Boolean Expressions SIEMENS Healthineers DICOM Header DICOM Header information can also be used in the configuration. Examples of DICOM Header information can be found in the Patient Browser on the Instances level. Open it by right-clicking the instance. View as Read-Only Instances View as Read-Only with Send to Archive Ctrl+Shift+5 Set Archive state Correct Split to New Series ? X Delete Right-click Configuration of data Loaded Del Display DICOM Header 4 15 State Definition MR.SUB_dynamic.latest • The term is within these square brackets → [ ]. [MR. Dynamic4D.][(0008,0008)(Contains)(Sub)][(0008, 103E) [(0008,0008)(Contains)(Sub)][latest][Result]:: 1 and 2 and !3 [MR. Dynamic4D.][(0008,0008)(Contains)(Sub) (0008, 103E). • Within these square brackets, 3 round brackets form the term. All 3 brackets need to be filled → [ ( )( )( ) ]. [MR. Dynamic4D.][{IsSubtraction}{Contains}{True}]::1 and 2 Implementation Version Name (0002,0013) SH 1 "SIEMENS" (7) Specific Character Set (0008,0005) CS Boolean Expression 1: 1 "ISO_IR 100" (10) CS 7 "ORIGINAL" (8) + - Current [MR][t2][cor][latest]::1 && Image Type (0008,0008) "PRIMARY" (7) "M" (1) Alternative "ND" (2) [(0008,0008)(Contains)(Sub)][latest][Result]::1 and 2 and 13 "NORM" (4) "FM" (2) "FIL" (3) Instance Creation Date (0008,0012) DA 1 1 "20100910" (8) OK Apply Save Cancel Instance Creation Time (0008,0013) TM 1 1 "175356.437000" (13) 10 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Configuration with Boolean Expressions SIEMENS Healthineers Example In this example: [(0008,0008)(Contains)(Sub)][latest][Result] :: 1 and 2 and !3 Configuration of data Loaded ? × [(0008,0008)(Contains)(Sub)] = 1 State Definition This is one term MR.SUB_dynamic.latest [MR. Dynamic4D.][(0008,0008)(Contains)(Sub)][(0008, 103E). latest 2 [(0008,0008)(Contains)(Sub)][latest][Result]:: 1 and 2 and !3 = Result !3 [MR.Dynamic4D.][(0008,0008)(Contains)(Sub)][(0008, 103E). = [MR. Dynamic4D.][{IsSubtraction}{Contains}{True}]::1 and 2 Load the series with the text Sub in the DICOM Header position 0008,0008. + Boolean Expression 1: Current [MR][t2][cor][latest]:: 1 && Additionally, the series is the latest one and is not a Result. Alternative [(0008,0008)(Contains)(Sub)][latest][Result]:: 1 and 2 and !3 OK Apply Save Cancel 11 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 MR Configuration with Boolean Expressions SIEMENS Healthineers Terms The information used for the configuration needs to be in the series name. Examples for the terms: Configuration of data Loaded ? X [ ] The term is in the series name State Definition MR.11_sag.latest [X] [Y] :: (1 or 2) Either term X or term Y is in the series name [t1][sag][latest][post]:: 1 and 2 and 3 and 14 [ ( )( )( ) ] The term is in the DICOM Header [t1][sag][latest][se][f12d][tse][post]:: 1 and 2 and 3 and (4 or 5. [t1][latest][mpr][post]:: 1 and 2 and 3 and !4 [t1][sag][latest][blade][post]:: 1 and 2 and 3 and 4 and !5 Examples for the command: 1 and 2 + Boolean Expression 1: - Current [MR][t2][cor][latest]:: 1 && 1 && 2 Alternative (x or y) ! = NOT OK Apply Save Cancel You can find the examples for the patient currently loaded in the small dialog box. Copy the content to a notepad or Word document by using the following keyboard shortcuts: Ctrl + A and Ctrl + C Paste to notepad: Ctrl + V 12 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Creating own Expressions SIEMENS Healthineers There are 3 ways to create a configuration: Series 15 1. Create a new layout or select an existing factory layout Add Study 2. Drag and drop some images to the segment for accessing the Data to be loaded dialog 3. For the following use cases, different ways of configuring can be used: # Series Name Current • Use the exact series name → Use drag and drop MR, 6/16/2014 • *Star rule* → Works well if there is only one criteria which is searched for within the Trauma series name 5 t1_se sag 320 • [Boolean expression] → Works well when searching for more than one criteria within 6 resolve_3scan_trace_tra_1 ... the series name 7 resolve_3scan trace_tra_1 ... 8 t2_tse_tra 9 t2_tirm_tra_dark-fluid_¡Pat 14 Mag_Images 15 Pha_Images 16 mIP_Images(SW) 17 SWI_Images 18 TOF_3D_multi-slab 31 t1_mprage_sag_p2_iso_1.0 13 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Creating own Expressions SIEMENS Healthineers Boolean Expression Alternative When generating an own expression, it needs to be set as Boolean Expression Alternative. The default will be Configuration of data loaded ? X Equality Ignore Case Alternative, which is looking for a series that is written exactly this way. State Definition Right-click MR.t1_se_sag_320.latest [t1][se][sag]::1 and 2 and 3 Right-click the expression and select Boolean Equality Alternative Ctrl+E • Expression Alternative Equality Ignore Case Alternative Ctrl + 1 Regular Expression Alternative Ctrl+R • Click Apply and Save. When the yellow or green Boolean Expression Alternative Ctrl+B traffic light appears, the expression works + Boolean Expression 1: Current [MR][t2][cor][latest]:: 1 && Configuration of data Loaded ? X Alternative State Definition [t1][se][sag]::1 and 2 and 3 [t1 ][se][sag]:: 1 and 2 and 3 MR.t1_se_sag_320.latest OK Apply Save Cancel 17 Boolean Expression 1 Current [MR][12][cor][latest]::1 && Q + Alternative [t1][se][sag].: 1 and 2 and 3 OK Apply Save Cancel 14 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Creating own Expressions SIEMENS Healthineers TOF Series Search for TOF series: Series 15 • Use the exact series name → Use drag and drop Add Study • *TOF* • [TOF]::1 → Right-click and set as Boolean Expression Alternative # Series Name Current The options above are also valid to search for SWI, mIP, Pha, and Mag series. MR, 6/16/2014 If the same word is found within another series name, the most recent series Trauma will be loaded. 5 t1_se_sag_320 6 resolve_3scan_trace_tra_1 ... 7 resolve_3scan_trace_tra_1 ... t2 tse tra CO 9 t2_tirm_tra_dark-fluid_iPat 14 Mag_Images 15 Pha_Images 16 mIP_Images(SW) 17 SWI_Images 18 TOF_3D_multi-slab 31 t1_mprage_sag_p2_iso_1.0 15 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 Creating own Expressions SIEMENS Healthineers Example Search for t2 and tra. In this example, we are looking for two words and Boolean Series Expression Alternative needs to be used. 15 Add Study • [t2][tra]::1 and 2 → Right-click and set as Boolean Expression Alternative # Series Name In this example, there are two series in which the word is found. The system will load Current t2_ tirm_tra_dark-fluid_iPat. MR, 6/16/2014 Trauma To load the t2_tse_tra, a more defined expression needs to be created or certain words 5 t1_se_sag 320 need to be excluded: 6 resolve_3scan_trace_tra_1 ... 7 resolve_3scan_trace_tra_1 ... • [t2][tse][tra]::1 and 2 and 3 → Right-click and set as Boolean Expression Alternative t2 tse tra CO • [t2][tra][tirm]::1 and 2 and !3 → Right-click and set as Boolean Expression Alternative 9 t2_tirm_tra_dark-fluid_iPat 14 Mag_Images 15 Pha_Images 16 mIP_Images(SW) 17 SWI_Images 18 TOF_3D_multi-slab 31 t1_mprage_sag_p2_iso_1.0 16 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 17 Effective Date: 08 Oct 2021| HOOD05162003228339 Unrestricted © Siemens Healthineers, 2021
- syngo.via
- MR
- job aid
- JA
- advanced configuration
- data loaded
- boolean
- boolean expressions