syngo.via - CT Coronary Vessel Definition
syngo.via - CT Coronary Vessel Definition step by step
syngo.via® CT Coronary Vessel Definition syngo.via CT Coronary is a full-featured software package designed to aid in the diagnostic evaluation of car- diac CT angiography (CTA) volume data sets. CT Coronary provides general evaluation tools, vessel defini- tion tools, and vessel evaluation tools that support in the identification and quantification of coronary le- sions and other cardiac anomalies. 1. From the Patient Worklist, load an appropriate data set into the CT Coronary Workflow: • If the examination has been correctly mapped, double click to load • If manual mapping is required, right-click the examination and select Open With > CT Coronary 2. As a part of the preprocessing, the major coronary arteries and branches are automatically traced and labeled in the CT Coronary workflow step. Additional centerlines can be defined using the tools available in the Case Navigator. RCA CT Coronary H CorCTA_0.75mm -IT 139.1 Isolate Coronar Marker Heart Tree Remove Blood A Manual Vessel SURF Detailed Plane Tree Vessel Definition RCA 5cm lip VRT A Manual Single Click Clicks Point Edit 3. The Manual tracing tool allows for the manual creation of centerlines based on clicked points or a drawn line. Manual tracing is helpful in difficult cases – like high-grade stenosis – and it is recommended to perform the vessel tracing on the MPR images rather than the VRT. It is important to note that manually created centerlines are not propagated to other car- Manual diac phases for a multi-phase dataset. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/26/17 | HOOD05162002613574 Job Aid | syngo.via CT Coronary Vessel Definition Effective Date: 06/26/17 | HOOD05162002613574 • To create a centerline based on clicked points, activate the Manual Vessel Tracing icon. On the vessel of interest, start a new centerline by clicking the center of the lumen. Click consecutive points along the vessel, and double click to end the tracing. • To create a centerline based on a drawn line, activate the Manual Tracing icon. Drag the mouse pointer along the vessel to create a freehand centerline. Use the undo icon to delete a last step, if necessary. Double click to end the tracing. 4. The Single Click Vessel Tracing tool allows for the semi-automatic creation of centerlines based on a single click in the desired vessel. With the icon activated, set a seed point by clicking once on the target vessel in an MPR, VRT, or CPR image. For optimum results, place the seed point in the center of the vessel lumen. syngo.via automatically creates a centerline start- Single ing at the ostium and continuing as far as possible distally. R 30.0'% 5. The Multiple Click Vessel Tracing tool allows for the semi-automated creation of centerlines based on multiple points placed along a vessel. With the icon activated, click the target vessel to set the start point. A rubber band is displayed between the mouse pointer and the start point. Continue clicking the target vessel until all points are set. In many cases a start Multiple and end point are all that are required. Double click to end the tracing. You can set the end point on a different image segment. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/26/17 | HOOD05162002613574 Page 2 of 5 Job Aid | syngo.via CT Coronary Vessel Definition Effective Date: 06/26/17 | HOOD05162002613574 6. If a centerline does not follow the desired course, the path can be changed manually or semi-auto- matically using Freehand Edit or Control Point Edit. Control points are automatically set at relevant positions along the centerline and divide a part of the centerline into two. Modifications done in one of the sections do not affect other parts. Control Paint Edit CT Coronary CT Coronary Tree Remove Marker Blood Control Point Edit Manual Plane Freehand Edit Vessel Definition Manual Che Point Edit • To modify centerlines by freehand editing, enable the Freehand Edit icon. The centerline is dis- played in magenta with control points. Click anywhere on the cen- terline and drag the mouse pointer to draw a new line or use consec- utive mouse clicks to drop new points. Double click at the end point of the modified centerline. Control Point Edit Freehand Edit • To modify centerlines by control point editing, enable the Control Point Edit icon. The centerline is displayed in magenta with control points. In the CPR segment, use the mouse to drag a control point to a desired location. To add additional control points, right click the centerline at the desired location and choose Add Control Point or simply left click the centerline at the desired location to add a new control point. An updated centerline is calculated that runs through the new point(s). Control Point Edit Freehand Edit SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/26/17 | HOOD05162002613574 Page 3 of 5 Job Aid | syngo.via CT Coronary Vessel Definition Effective Date: 06/26/17 | HOOD05162002613574 • To delete part of a centerline, enable either of the editing tools. Right click on the desired center- line area and select Discard Centerline Above or Discard Centerline Below. • To extend a centerline, lengthen the freehand line or add control points. With the centerline edit mode active, click the end point of a centerline and draw or add consecutive points. Double click to end the extension. • To merge two coronaries, activate the Extend functionality by clicking on the proximal end point of one vessel and add an extension point at the ostium of the other vessel and along the vessel to be traced. Double click to end the extension. • To delete a centerline or delete the centerline and the lumen, right click on the centerline and select the desired +50 mm action. -2 5 mm Rename to 00 mm Control Point Edit Freehand Edit Delete Centerline 5 mm Delete Centerline and Lumen 50 mm 7. Cinematic Rendering – in the lower left segment menu – enables a photorealistic 3D volume render- ing display RHP ARF Angio View Cinematic VRT HO VRT MIP MPR 8. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/26/17 | HOOD05162002613574 Page 4 of 5 Job Aid | syngo.via CT Coronary Vessel Definition Effective Date: 06/26/17 | HOOD05162002613574 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/26/17 | HOOD05162002613574 Page 5 of 5
- syngo.via VB20 - CT Coronary Vessel Definition