syngo.via - CT Dual Energy Monoenergetic Plus
syngo.via - CT Dual Energy Monoenergetic Plus step by step
syngo.via® CT Dual Energy Monoenergetic Plus The syngo.via CT Monoenergetic Plus application class simulates images that are equivalent to images scanned with a single photon energy beam, depending on the energy (keV). By changing the energy (keV), you can enhance the contrast between different materials. Compared to the Monoenergetic viewing mode, Mo- noenergetic Plus provides an improved algorithm for noise reduced images, parallel display of multiple ROIs and their curves, and the ability to save this ROI information for statistical evaluations. 1. From the Patient Worklist, load an appropriate data set into the CT Dual Energy Workflow: • If the examination has been correctly mapped, double click to load Monoenergetic Plus V Resolution • If manual mapping is required, right-click the examination and 2 select Open With > CT Dual Energy Minimum [HU] 950 Default • When data is loaded into syngo.CT Dual Energy, relevant ap- Maximum [HU] 3071 plication classes are also loaded. Select the Monoenergetic Basic Algorithm Calculate Plus application class Export Statistics 2. In the upper right in-segment tool menu, select the Monoenergetic Plus ROI tool, which enables the drawing of ROIs for evaluating the mean CT value as a function of photon energy. Draw an ROI in the tissue of interest. Distance Line Dual Energy ROI Circle Pixel Lens Marker Arrow Angle Text T Monoenergetic Plus ROI SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 5/4/2017| HOOD05162002591627 Job Aid | syngo.via CT Dual Energy Monoenergetic Plus Effective Date: x/x/xx| HOOD05162002614781 Effective Date: 06/29/17 3. The Monoenergetic Plus diagram in the lower right segment displays spectral information for the drawn ROIs: CT Value [HUI Showing last 5 findings Finding App: 100/ Sn140/70 key Mean: 78.9/68.4/ 78.9 HU Stddev: 20.9/16.5/ 18.0 HU Area: 2.6 cm2 120 - Energy Net 00 100 110 120 130 140 150 100 170 180 190 4. To change the Monoenergetic keV setting: • In the mini toolbar, move the Monoenergetic keV slider to the desired keV value, or in the diagram segment move the vertical magenta line to the left or right. App: 100/ Sn140/50 keV App: 100/ Sn1 40/70 keV Mean: 37.2/ 34.7/ 38.0 HU App: 100/ Sn1 40/120 keV Mean: 37 2/ 34.7/ 48.3 HU Stddev: 15.9/ 15.1/ 22.6 HU Stddev: 15.9/ 15.1/14.0 HU Mean: 37.2/ 34.7/ 31 3 HU Area: 0.9 cm2 Area: 0.9 cm2 Stddev: 15.9/15.1/9 0 HU Area: 0.9 cm2 Monoenergetic Monoenergetic Monoenergetic 50 190 40 70 190 E 40 120 190 Showing last 5 findings Finding Showing last 5 findings Finding CT value [HU Showing last 5 findings Finding CT Value [H 70 50 - Energy key nergy key Energy Ikel 80 90 100 110 120 130 140 150 160 170 180 50 20 80 80 100 110 120 130 140 150 160 170 180 0 140 150 160 170 180 190 50 keV 70 keV 120 keV • In this example, note the change in the conspicuity of the liver lesion at the various keV values. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/4/2017| HOOD05162002591627 Page 2 of 4 Job Aid | syngo.via CT Dual Energy Monoenergetic Plus Effective Date: x/x/xx| HOOD05162002614781 Effective Date: 06/29/17 5. Independent of the report based on the findings in the Report Navigator, results can be exported for all Monoenergetic Plus ROIs to the file system. • Snapshots of all segments as .png files • Snapshots of all Monoenergetic ROIs • A text file that lists mean values and standard deviations of all Monoenergetic Plus ROIs • To export the Monoenergetic Plus ROI properties: • Click the Export Monoenergetic ROIs to File System icon Export Statistics • Browse to the desired folder and click OK. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/4/2017| HOOD05162002591627 Page 3 of 4 Job Aid | syngo.via CT Dual Energy Monoenergetic Plus Effective Date: x/x/xx| HOOD05162002614781 Effective Date: 06/29/17 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively ŶOperator Manualŷ) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator’s Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively ŶFunctionalityŷ) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright “ Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/4/2017| HOOD05162002591627 Page 4 of 4
- syngo.via - CT Dual Energy Monoenergetic Plus