syngo.via - CT Vascular Vessel Definition
syngo.via - CT Vascular Vessel Definition Step by Step
syngo.via® CT Vascular Vessel Definition syngo.via CT Vascular is a full-featured software package designed to aid in the diagnostic evaluation of CT angiography (CTA) volume data sets. CT Vascular provides general evaluation tools, vessel definition tools, and vessel evaluation tools that support in the identification and quantification of vascular lesions and other vessel anomalies. 1. From the Patient Worklist, load an appropriate data set into the CT Vascular Workflow: • If the examination has been correctly mapped, double click to load • If manual mapping is required, right-click the examination and select Open With > CT Vascular 2. As a part of the preprocessing, major vessels – e.g. aorta, renal arteries, carotid arteries - are automati- cally traced and labeled in the CT Vascular workflow step. Additional centerlines can be defined using the tools available in the Case Navigator. CT Vascular Q + -IT Remove Table Bone Remoy .. . Edit Remove Marke Bones A Manual Vessel Plane SURF 2.5 Vessel Definition Runoff r - Manual Multiple Control Clicks Point Edit 3. The Manual tracing tool allows for the manual creation of centerlines based on clicked points or a drawn line. Manual tracing is helpful in difficult cases – like high-grade stenosis – and it is recom- mended to perform the vessel tracing on the MPR images rather than the VRT. Manual SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 5/8/2017| HOOD05162002591655 Job Aid | syngo.via CT Vascular Vessel Definition Effective Date: 5/8/2017| HOOD05162002591655 • To create a centerline based on clicked points, activate the Manual Vessel Tracing icon. On the vessel of interest, start a new centerline by clicking the center of the lumen. Click consecutive points along the vessel, and double click to end the tracing. • To create a centerline based on a drawn line, activate the Manual Vessel Tracing icon. Drag the mouse pointer along the vessel to create a freehand centerline. Use the undo icon to delete a last step, if necessary. Double click to end the tracing. 4. The Multiple Click Vessel Tracing tool allows for the semi-automated creation of cen- terlines based on multiple points CL placed along a vessel. With the icon Multiple activated, click the target vessel to set the start point. A rubber band is dis- played between the mouse pointer and the start point. Continue clicking the target vessel until all points are set. In many cases a start and end point are all that are required. Double click to end the tracing. You can set the end point on a different im- age segment. 5. If a centerline does not follow the desired course, the path can be changed manually or semi-auto- matically using Freehand Edit or Control Point Edit. Control points are automatically set at relevant positions along the centerline and divide a part of the centerline into two. Modifications done in one of the sections do not affect other parts. CT Vascular @ + -IT Control Point Edit Remove Edit Control Point Edit Table bone Remov ... Bones Remove Marker Calcium Freehand Edit Manual Vessel Plane SURF Vessel Definition Manual Multiple Contro Clicks Point Edit SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/8/2017| HOOD05162002591655 Page 2 of 4 Job Aid | syngo.via CT Vascular Vessel Definition Effective Date: 5/8/2017| HOOD05162002591655 • To modify centerlines by freehand editing, enable the Freehand Edit icon. The centerline is displayed in magenta with control points. Click anywhere on the centerline and drag the mouse pointer to draw a new line or use consecutive mouse clicks to drop new points. Double click at the end point of the modified centerline. Control Point Edit Freehand Edit • To modify centerlines by control point editing, enable the Control Point Edit icon. The centerline is displayed in magenta with control points. In the CPR segment, use the mouse to drag a control point to a desired location. To add additional control points, right click the centerline at the de- sired location and choose Add Control Point or simply left click the centerline at the desired loca- tion to add a new control point. An updated centerline is calculated that runs through the new point(s). Control Point Edit Freehand Edit • To delete part of a centerline, enable either of the editing tools. Right click on the desired center- line area and select Discard Centerline Above or Discard Centerline Below. • To extend a centerline, lengthen the freehand line or add control points. With the centerline edit mode active, click the end point of a centerline and draw or add consecutive points. Double click to end the extension. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/8/2017| HOOD05162002591655 Page 3 of 4 Job Aid | syngo.via CT Vascular Vessel Definition Effective Date: 5/8/2017| HOOD05162002591655 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 5/8/2017| HOOD05162002591655 Page 4 of 4
- syngo.via - CT Vascular Vessel Definition