syngo.via MR VB50 Delta Online Training
This online training is intended to train you on new features and improvements included in the syngo.via VB50 software version covering Magnetic Resonance Imaging.
This course is best viewed on either a tablet, laptop, desktop or connected monitor. Not recommended to view on a smartphone.
Continue Continue syngo.via MR VB50 Delta Online Training syngo.via MR VB50 Delta Online Training In this training you will learn about the new features and improvements included in the syngo.via VB50 software version covering Magnetic Resonance Imaging. Describe the new Siemens Healthineers User Interface (SHUI) 1 List the improvements in MR Cardiac Analysis 3 Understand the functionality of AIRC Prostate MR 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Welcome [audf_sv_vb50_delta_olt_mr_welcome.mp3] Audio Script: Welcome to the syngo.via MR VB50 Delta Online Training. In this training you will learn about the new features and improvements included in the syngo.via VB50 software version covering Magnetic Resonance Imaging. By the end of this training, you will have achieved the three learning objectives listed on the right. Let’s get started. Hints for Navigating this Online Training Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 3 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. Some pages show an X button in the upper right corner. Click the X button to return to the overview page and not miss any information provided. Some images show a magnifier icon. Click on the icon to see an enlarged view of the image. Another click brings you back to the normal view. Enjoy the course! Hints for Navigation SHUI Siemens Healthineers User Interface What‘s New dialog syngo News SHUI [audf_sv_vb50_delta_olt_mr_shui.mp3] Audio Script: Siemens Healthineers now provides a new clear and calm user interface throughout all the new Siemens Healthcare products and service portfolios. Using the same framework across all the portfolio makes it easy to learn how to use and operate our products as well as switch between modalities or devices. The What‘s New dialog is an automatic notification window displayed after logging into syngo.via for the first time. It gives you the opportunity to see the top new features included in syngo.via VB50 at a glance. The syngo News is our new information channel. Here you will find useful tips and tricks on how to use syngo.via, workflow enhancements, as well as information about events near you that can benefit you in your daily work. AI-Rad Companion (AIRC) Prostate MR on syngo.via The new Prostate Lesions* functionality provides Automatic Prostate Segmentation Automatic Lesion Detection Workflow guided layout Pre-populated results and findings PI-RADS 2.1 reporting * Prostate Lesions requires an additional license. The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AI-Rad Companion (AIRC) Prostate MR on syngo.via [audf_sv_vb50_delta_olt_mr_airc-prostate-mr-overview.mp3] Audio Script: In the MR Prostate Reading step you can read MR images of the prostate. With the new AI-Rad Companion Prostate MR license, you get the Prostate Lesions functionality, which automatically detects lesions and classifies them with a score. Prostate Lesions provides several new features for the user. For example: Automatic Prostate Segmentation Automatic Lesion Detection A workflow guided layout Pre-populated results and findings and PI-RADS 2.1. reporting All of this is calculated fully automatically during pre-processing. When opening the workflow, all of these results are already available to the user for reading. Learn more about each step on the following pages. In MR Prostate Reading Select the Prostate Lesions icon A new image layout opens Lesion candidates are displayed in the lower left corner Multiparametric MR series are displayed: transversal T2, DWI, high (calculated) b-value and DCE series AIRC Prostate MR Confirmation Layout The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Confirmation Layout [vid_sv_vb50_delta_olt_mr_airc-prostate-mr-confirmation-layout.mp3] Video Script: In the MR Prostate Reading step, select the Prostate Lesions icon. This opens a new layout that will guide you in verifying and confirming potential lesions. The layout shows the input images: T2 transversal high b-value image, or calculated b-value if available ADC map and dynamic T1 and T2 sagittal in dual monitor set up. In the lower row a fusion of the transversal T2 series and the Suspicion Map, the prostate contour, the non-peripheral zone, and contours of the potential lesions are displayed. In the Lesions preview segment, details of the currently selected lesion candidate are displayed. If necessary, adding another series from the Series Navigator is possible. The common measurement tools including Mean Curve are available. AIRC Prostate MR Input data Input data criteria For successful lesion detection, the input data must meet the following criteria: The product is still under development and not commercially available in the US. Its future availability cannot be ensured. Table with 2 columns and 1 rows DWI b-values Low b-value: 0 – 100 (recommended: b=50) High b-value: ≥ 800 (recommended: around 1,000) Table with 2 columns and 1 rows Orientation of T2 and DWI series Transversal (strict transversal or anatomical) Table with 2 columns and 1 rows T2 sequences T2 TSE or SPACE Table with 2 columns and 2 rows Scan parameter Value Field strength 1.5 T – 3 T AIRC Prostate MR Input data [audf_sv_vb50_delta_olt_mr_airc-prostate-mr-input-data.mp3] Audio Script: For successful lesion detection, the input data must meet the following criteria: The system requires images from a 1.5 Tesla or 3 Tesla system. As a T2 sequence type T2 Turbo Spin Echo or SPACE series are used. As Diffusion Weighted images ep2d, resolve or zoomIt sequence can be used. The orientation of T2 and Diffusion Weighted series has to be strictly transversal or anatomical. From Diffusion Weighted images, at least two different b-values are required. As a Low b-value b50 is recommended, and as a High b-value around 1,000 is recommended. Based on all the input data, the system calculates a suspicion map which displays the potential lesions. AIRC Prostate MR Suspicion Map The Suspicion Map is calculated during pre-processing by a Deep Learning algorithm, using the T2 and Diffusion Weighted images as input. The potential lesions are displayed in this Map. The Suspicion Map is black if there are no lesions detected. The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Suspicion Map [audf_sv_vb50_delta_olt_mr_airc-prostate-mr-suspicion-map.mp3] Audio Script: The Suspicion Map is calculated during preprocessing by a Deep Learning algorithm, using the T2 transversal and Diffusion Weighted images as input. The potential lesions are displayed in this Map. The Suspicion Map is black if there are no lesions detected. The Suspicion Map is a parametric map that can be fused with a morphological series. It can be sent to PACS if this is enabled in the MR Prostate Workflow Properties. If the pre-processing fails, then the Suspicion Map is not available in the Series Navigator. We will take a closer look at pre-processing requirements later in this training on the "Additional Information" page. Lesion candidates listed in lower left segment Details of currently selected lesion are displayed in Preview segment All lesions candidates need to be confirmed or deleted Confirmed lesions are pre-populated in Findings Assistant and report, including score and location AIRC Prostate MR Confirming Lesions The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Confirming Lesions [vid_sv_vb50_delta_olt_mr_airc-prostate-mr-confirming-lesions.mp3] Video Script: With automatic lesion detection, the system provides the segmentation of the prostate gland, the non-peripheral zone and the potential lesions. For all potential lesions, the corresponding information on volume, region, laterality, location, score and Level of Suspicion is displayed in the preview. On the lesion tabs, the lesion with the highest score is shown first. If you select a Lesion tab, the lesion candidate is displayed in all segments of the layout. The details of the selected lesion are displayed in the Lesion preview area. They can be changed if necessary. In addition to the lesion score, a Level of Suspicion is calculated for each lesion. This Level of Suspicion provides a more granular assessment of lesion suspiciousness than the lesion score. The Level of Suspicion may support you when validating results. It will not be part of the findings information or reporting. The text ”No lesion candidates are open for validation“ is displayed when all potential lesions have been confirmed or rejected. This information is also displayed if no lesions are detected. Findings Assistant is pre-populated with findings of: Gland volume Confirmed lesions Values editable in findings details tab PI-RADS 2.1 guideline is used when filling sub scores in findings details All added findings are part of final report AIRC Prostate MR Findings and Reporting The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Findings and Reporting [vid_sv_vb50_delta_olt_mr_airc-prostate-mr-findings-reporting.mp3] Video Script: The findings assistant is pre-populated with the gland volume, confirmed lesions and lesions location. They will also be displayed in the report. The findings can be edited. In the prostate template section, the gland volume can be edited and the PSA value can be added. When adding the PSA value, the PSA density is calculated automatically. In the findings section, the findings values and scores can be edited. Each lesion subscore can be filled in. When filling in the subscores, the PI-RADS 2.1 guideline is used. The broken link indicates that this specific combination of score and subscore is not following the recommendations of the PI-RADS 2.1. The broken link is also displayed when subscores are not used. Additional findings, such as the Mean Curve, can be added using the standard measurement and reporting tools. All findings and information in the findings assistant will be part of the report, which is a one-pager. With Save and Send all findings and the report are sent to PACS, if this is configured in the Administration Portal. AIRC Prostate MR Configuration Configuration of the automatic lesion detection can be done by a clinical administrator. Perform Automated Prostate Segmentation during pre-processing. This is mandatory. Publish Suspicion Map upon Save and Send Enable Auto Detection of input series for lesion detection When disabling the automatic detection, input data definition for morphology and Diffusion Weighted series can be used The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Configuration [audf_sv_vb50_delta_olt_mr_airc-prostate-mr-configuration.mp3] Audio Script: The configuration properties can be found in the MR Prostate Workflow properties. In the MR Prostate Reading step, click the gearwheel icon to open the MR Prostate Workflow Properties dialog box. Select the Workflow Configuration tab. Properties include: Perform Automated Prostate Segmentation during pre-processing, Publish Suspicion map upon Save and Send, and Enable Auto Detection of input series for lesion detection with the series description for morphology and diffusion weighted series. For changing the configuration you need to log in as a clinical administrator. The Setting Perform Automated Prostate Segmentation during preprocessing is mandatory when using the Lesion detection functionality. The Setting Publish Suspicion map upon Save and Send is not activated by default. Upon activation, the suspicion map is sent to and archived in PACS. When the setting Enable Auto Detection of input series is selected, the input data for Morphology and Diffusion Weighted series are determined automatically. The system searches for T2 Weighted and Diffusion Weighted series, based on DICOM attributes. When deselecting this setting, a series description can be added for the series to be used. AIRC Prostate MR Additional Information Please note Good and sufficient image quality of the input data is important Validation of the segmentation is important Validation of the lesions is important Only lesions classified with score 3, 4 or 5 are displayed The Suspicion Map will not be updated if some lesions are deleted or not approved Possible user messages Pre-processing may fail if the image data configured for segmentation is not available The product is still under development and not commercially available in the US. Its future availability cannot be ensured. AIRC Prostate MR Additional Information [audf_sv_vb50_delta_olt_mr_airc-prostate-mr-additional-information.mp3] Audio Script: Some additional information and precautions can be useful when operating with the AIRC Prostate MR. Sufficient image quality of the input image series is important. Please validate the quality prior to using images for lesion detection. Insufficient image quality can lead to incomplete or incorrect prostate lesion detection. Improper segmentation of the prostate can lead to incomplete or incorrect prostate lesion detection. Please note that the prostate lesion detection only includes potential lesions classified with score 3, 4 or 5. The Suspicion Map will not be updated if some lesions are deleted or not approved. Pre-processing may fail if the image data configured for segmentation is not available. In this case, a user message is displayed, explaining the reason for the failure. If pre-processing fails, there is no Suspicion Map in the Series Navigator, and the Preview Segment is empty. Cardiac Analysis Create Findings button is available in each workflow step Findings Assistant is now also available in MR Cardiac Analysis MR Cardiac Analysis [audf_sv_vb50_delta_olt_mr_cardiac-analysis.mp3] Audio Script: The Findings Assistant is now also available in the MR Cardiac Analysis Workflow. The Create Findings button is available in each workflow step. List the improvements in MR Cardiac Analysis Understand the functionality of AIRC Prostate MR Describe the new Siemens Healthineers User Interface (SHUI) Course Review Congratulations. You have completed the syngo.via MR VB50 Delta Online Training course. Select the objectives listed below to review the material before proceeding to the final assessment. 1 1 1 2 2 2 3 3 3 Course Review Cardiac Analysis The Findings Assistant is now also available in MR Cardiac Analysis. The Create Findings button is available in each workflow step. AIRC Prostate MR The new Prostate Lesions functionality provides automatic prostate segmentation, automatic lesion detection, a workflow guided layout, pre-populated results and findings, and PI-RADS 2.1 reporting. The Suspicion Map is calculated during pre-processing by a Deep Learning algorithm, using the T2 and Diffusion weighted images as input. If there are no lesions detected, the Suspicion Map is black and the text “No lesion candidates are open for validation“ is displayed. With automatic lesion detection, the system provides the segmentation of the prostate gland, the non-peripheral zone and the potential lesions. For all potential lesions, the corresponding information about volume, region, laterality, location, score and Level of Suspicion is displayed in the preview. Confirmed lesions are pre-populated in the Findings Assistant and the report, including score and location. Configuration of the automatic lesion detection can be done by a clinical administrator in the MR Prostate Workflow Properties. SHUI The Siemens Healthineers User Interface provides a clear and calm user interface throughout all new Siemens Healthcare products and service portfolios. What‘s New in this version is an automatic notification window that is displayed after logging into syngo.via. It shows the top new features included in syngo.via VB50 at a glance. The syngo News dialog provides useful tips and tricks on how to use syngo.via, workflow enhancements and information about events. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters / Siemens Healthcare GmbH / Henkestr. 127 / 91052 Erlangen, Germany Telephone: +49 9131 84-0 / siemens-healthineers.com Disclaimer Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment … is calculated fully automatically. … cannot be sent to PACS. … is calculated by a Deep Learning algorithm. … uses T2 and Diffusion Weighted images as input. Question 1 of 5 The Suspicion Map … Select three (3) answers. Question 1 Correct Incorrect One or more answers are incorrect. Segmentation of the hip Segmentation of the prostate gland, the non-peripheral zone and the potential lesions Volume, region, laterality, location, score and the Level of Suspicion of the potential lesions Question 2 of 5 What will be available as a result of the Prostate Lesions functionality? Select two (2) answers. Question 2 Correct Incorrect One or more answers are incorrect. The text “ No lesion candidates are open for validation.“ is displayed. The Suspicion Map is black. There is no information about this for the user. Question 3 of 5 When no lesions are detected … Select two (2) answers. Question 3 Correct Incorrect One or more answers are incorrect. Only confirmed Prostate Lesions. All lesions detected by the system. Only lesions classified with a score of 4 or 5. What Prostate Lesions findings are part of the report? Question 4 of 5 Select the best answer. Question 4 Incorrect Incorrect Correct Publish Suspicion map upon Save and Send. Auto save all results. Enable Auto Detection of input series for lesion detection. Series description definition for morphology and diffusion weighted series. Question 5 of 5 What can be configured in MR Prostate Workflow Properties ? Select three (3) answers. Question 5 Correct Incorrect One or more answers are incorrect. Review Review Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the syngo.via MR VB50 Delta Online Training. Completion syngo.via MR VB50 Delta OLT [HOOD05162003114248 | Effective Date: 01 SEP 2020] 1.1 Welcome 1.2 Hints for Navigation 1.3 SHUI 1.4 AI-Rad Companion (AIRC) Prostate MR on syngo.via 1.5 AIRC Prostate MR Confirmation Layout 1.6 AIRC Prostate MR Input data 1.7 AIRC Prostate MR Suspicion Map 1.8 AIRC Prostate MR Confirming Lesions 1.9 AIRC Prostate MR Findings and Reporting 1.10 AIRC Prostate MR Configuration 1.11 AIRC Prostate MR Additional Information 1.12 MR Cardiac Analysis 1.13 Course Review 1.14 Disclaimer 1.15 Assessment
- syngo.via
- VB50
- Magnetic Resonance Imaging
- Delta
- syngovia
- snygo
- via