syngo® Volume Perfusion CT Neuro (VPCT Neuro)
syngo® Volume Perfusion CT Neuro (VPCT Neuro) step by step
syngo® Volume Perfusion CT Neuro (VPCT Neuro) Computed Tomography 1. From the Patient Browser, load an appropriate Neuro Perfusion data set into the VPCT Neuro application. Local Database_ SD AS+_VPCT_Stroke_F_ ////@-14_Feb_20]] [14] VPCT DynMulti4D 5.0 H20f Scheduler SD_CaScoring DVD_R SD Case_o_Month03/09 DVD_ROM SD DE LUNG_NODULE: R///// 2. From the Organ Gallery, select the type of Neuro evaluation desired. For fast and comprehensive stroke evaluation, choose Auto Stroke MTT. Organ Gallery Auto Stroke Auto Stroke Stroke Stroke MTT Turnor Customized MTT Stroke Customized Customized Stroke MIT Tumor Please select the application .. 3. The "Auto" workflows will automatically perform the Motion Correction and Segmentation (bone/cranium removal) steps. SO_AS-_VPCT_! nation UIT A Filming SIEMENS siemens.com/healthineers Healthineers Job Aid | syngo® Volume Perfusion/VPCT Neuro Effective Date: 12/27/2017| Quality 4957 4. On the Vessels step, modify the symmetry plane by rotating/moving the green orientation lines in both segments 2 and 3. SO_AS._VPCT. Motion Correction ROI n | VPCT Neuro 5. Evaluate the vessel curves in segment 4. If adjustments need to be made, redefine the arterial and venous reference vessels or adapt the threshold for vessel detection using the icons on the Vessels subtask card. Click the blue check icon to proceed. M Reference Vessel Left hemisphere Normalized Arterial Curve Right hemisphere 1: Motion Correction 1: Motion Correction 1: Motion Correction Vessel CT[HU] Tissue CTIHU 2: Segmentation 2: Segmentation 2: Segmentation 600 20 3: Vessels 3: Vessels 3: Vessels 400 10 200- 200- Max Enh. [HU] Max Enh [HU] Max. Enh. [HU] 25 150 100 25 Timets! 197 80 497.80 497.80 Baseline Delme Reference Vessel Earliest Start Rel. Thresh. [% Rel: Thresh. [%] Rel. Thresh. [%] Latest Start 10: 10 10 Earliest Peak Define Vessels Latest Peak 25.504 Pallak ROS Define Artery 0.00 W automatic Shi 4: Normalization 4: Normalization 4. Normalization Siemens Healthineers Services Page 2 of 4 Job Aid | syngo® Volume Perfusion/VPCT Neuro® Volume Perfusion/VPCT Neuro9B Effective Date: 12/27/2017| Quality 49575 6. Normalization improves the display of the CBF and CBV images and is automatically calculated based on histograms of the non-ischemic region. To change the automated selection, use the desired icon on the Normalization subtask rd. Click the Calculate icon to proceed. SD.AS+_VPCT. : Motion Correction 2: Soorientation 3. Vessels Norinsization F SD AS ore Toon ROL VPCT Neuro 7. If an Adaptive 4D Volume data set was used, the axial images can be viewed in orthogonal projections by toggling with the Axial/Coronal/Sagittal View icon. 8. Quantitative information can be acquired using the tools on the ROI subtask card. Images can be saved using the tools on the Store subtask card. Store Tools ROI Store Tools ROI Threshold CBF CBV [ml/100ml/min] [ml/100ml] 00 Siemens Healthineers Services Page 3 of 4 Job Aid | syngo® Volume Perfusion/VPCT Neuro® Volume Perfusion/VPCT Neuro9B Effective Date: 12/27/2017| Quality 49575 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4
- syngo® Volume Perfusion CT Neuro (VPCT Neuro)