syngo.via VB40 Delta - Further Enhancements in MM Reading (Part 1) - USA
This online training (Part 1) is intended to train you on further enhancements in MM Reading as available with the syngo.via VB40 software
Upon successful completion of this online training, you will know about: The most important improvements in syngo.via MM Reading concerning: Resetting Windowing values by middle mouse button click syngo.via OpenApps Easy Reading New Navigation tool: Next-Previous study New Viewing Protocols Advanced visualization tools Please note: Some of the features are license dependent. Congratulations. You have completed the syngo.via VB40 Delta online training - Further Enhancements in MM Reading (Part 1). Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Select the link below to view and/or print your review material before proceeding to the final quiz. Download and print a copy of the Course Review. Further Enhancements in MM Reading (Part 1) A quick reset of windowing values can now be performed by double-clicking the middle mouse button / your scroll wheel respectively. The Easy reading functionality has been extended: Images with the same orientation are kept side-by-side when adding additional series using the drag and drop functionality from the Series Navigator in order to better support your routine reading. Easy navigation between time points is now possible using the new Next-Previous Study tool. When using comparison mode, this new functionality ensures that the later time point remains displayed in the layout, while only the prior studies are toggled. MM Reading now has viewing protocols. This new functionality allows you to change the preferred layouts on the fly. Siemens Healthineers introduces the Digital Marketplace as the new web store for syngo.via OpenApps, medical post-processing apps created by us or our partners. You are able to launch and use the syngo.via OpenApps within the MM Reading workflow. This allows you to focus on your case and exchange the results like snapshots from the App with MM Reading. The new CT Lung Change tool displays the changes in density across different time points, therefore making the comparison of current and prior studies faster and more reliable. The Evaluate Change functionality allows for a closer look at density changes in the image segment: Directly display original images without colour overlay in a lens, and toggle between timepoints to be displayed in the lens by clicking the left mouse button. The LungCAD functionality is enhanced with a new Navigation Tool to allow easy navigation of LungCAD marks. Furthermore, a lens is available, providing a zoomed view. The new multimodality tool Assisted Perpendicular allows easy creation of perpendicular distance lines and can, for example, be used for lesion evaluation across time points. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2019 Images courtesy of: Erasmus Medical Center, Department of Radiology, Rotterdam, The Netherlands Institut Jules Bordet, Department of Radiology, Bruxelles/Brussels, Belgium Kantonsspital Münsterlingen, Department of Radiology, Münsterlingen, Switzerland Klinikum der Ludwig-Maximilians-Universität, Department of Radiology, Munich, Germany Universitätsklinikum Tübingen, Department of Radiology, Tübingen, Germany Welcome to this syngo.via VB40 delta online training. In part 1 of this training you will learn about further enhancements in MM Reading that are available with the syngo.via VB40 software version. For further major enhancements in MM Reading, such as Interactive Spectral Imaging or MR General Tools, please see part 2 of this training available in the syngo.via training area of PEPconnect. Resetting Windowing values is now possible using your mouse buttons: Double-click the middle mouse button / your scroll wheel to change the window width and center to the default values. Easy reading functionality allows you to adapt the layout to the data loaded on the workflow with a simple click of the mouse. The display of multiple volumes has been adapted in the software version VB40. Images with the same orientation are kept side-by-side also in a multi-monitor setup. Easy navigation between time points is now possible using the new Next-Previous Study tool. When using comparison mode, this new functionality ensures that the later time point remains displayed in the layout, while only the prior studies are toggled. In order to change preferred layouts on the fly, MM Reading now offers you viewing protocols. Simply select a different layout rule from the drop-down in your Case Navigator in the Viewing Panel for optimal display of data, for example if a previous examination comes from a different modality. Siemens Healthineers introduces the Digital Marketplace* as the new web store for syngo.via OpenApps, medical post-processing apps created by us or our partners. You can download, try out, subscribe and get instant access to the functionality you need. Support of multi-server deployments when Multi-Server Licensing is in place - install once, use everywhere available now. You are able to launch and use the syngo.via OpenApps directly out of the MM Reading worfklow. This allows you to focus on your case and exchange the results like snapshots from the App with MM Reading. *Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may not be commercially available in all countries. Please contact the legal manufacturer for more information. An overview about the syngo.via OpenApps at one glance is available in the Digital Marketplace. Find more details on the installations and license state in the Installed Apps section. *Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may not be commercially available in all countries. Please contact the legal manufacturer for more information. The Apps you have downloaded are now seamlessly integrated into MM Reading: Access them through the ‘OpenApps’ icon in your toolbar Find all installed Apps displayed as a list directly It is also possible to open multiple Apps simultaneously. You can choose, if you want to process all data loaded or a dedicated series with an installed syngo.via OpenApp. Using the APP Home button, you can always return to the adaptive overview layout displaying all data loaded. Returning to MM Reading is always possible: Click the ‘x’ in the OpenApps section in the Case Navigator, or Select any of the favorite layouts in the MM Reading Case Navigator This chapter introduces the following enhancements and improvements in Advanced Visualization tools of MM Reading that are available with the syngo.via VB40 software version: CT Lung Change tool LungCAD* improved with Navigation Tool Assisted Perpendicular *LungCAD requires an additional license and might not be available in all countries, functionality might vary in different countries. The CT Lung Change tool allows you to quickly review and assess changes in density across different time points: It registers current and prior thorax examinations automatically, and Displays increasing and decreasing HU values as color coded overlays on all orientations. Use it together with the LungCAD* tool for evaluation of disease progression. *LungCAD requires an additional license and might not be available in all countries, functionality might vary in different countries. In MM Reading, the LungCAD functionality is enhanced with a new Navigation Tool: A mini toolbar has been introduced allowing easy navigation through the LungCAD marks. The lens view provides a zoomed view of the CAD marks and different windowing levels to enhance distinction between nodule components All accepted LungCAD marks are listed as findings in the Findings Assistant automatically *LungCAD requires an additional license and might not be available in all countries, functionality might vary in different countries. The new multi-modality tool Assisted Perpendicular allows: Easy creation of perpendicular distance lines Lesion evaluation across time points Usage for oncological or organ measurements. Lung Cancer Screening according to guidelines. The Evaluate Change functionality allows for a closer look at density changes in the image segment: Activate the tool using the corresponding button in the CT Lung Change dialog. Directly display original images without colour overlay in a lens. Toggle between timepoints to be displayed in the lens by clicking the left mouse button.
- syngo.via
- VB40
- Delta
- syngovia
- snygo
- via