Sysmex® CA-600 Series Analyzer Sample Processing Online Training
Create work orders, process samples, and identify sample status for accurate and timely patient results. This clinical laboratory training qualifies for continuing education units (CEU).
Congratulations. You have completed the CLINITEK Status®+ System hCG Quality Control Cassette Test Online Training Course. Once you have reviewed the information on this page, you may proceed to the assessment. Welcome to the Sysmex® CA-600 Series Sample Processing Online Training course. The steps to process samples include: Load samples in the rack Order tests manually or by Host Press Start Locate results Select Next to continue. Identify the sample processing areas of the Main Menu screen List the steps required to process samples Locate sample results in the Stored Data screen Upon successful completion of this course, you will be able to: Select Next to continue. If necessary, test records stored on the analyzer can be deleted from memory. Before doing performing this action, you may want to save database to an external source. Data saved on an LIS will not be deleted. Congratulations. You have completed the Sysmex® CA-600 Series Sample Processing Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Identify the sample processing areas of the Main Menu screen Rack Replacement: This indicates whether or not the sample rack can be replaced. Start: The Start key initiates processing. Test keys: The Test keys manually order test requests. Worklist: The worklist displays the rack number, sample orders, and the sample status during processing. Repeat key: The Repeat key duplicates a test order for an entire sample rack. ID No. Entry key: The ID Number Entry key displays a keypad for manual entry of the sample ID number. Test Group area: The Test Group area displays the selected group of tests. List the steps required to process samples Processing with Bi-directional interface Check Rack replacement status Load barcoded Samples Press Start Select First Tube or Continue Processing manually with barcoded samples Check Rack replacement status Load barcoded Samples Order tests for each sample Press Start Select First Tube or Continue Processing manually with non-barcoded samples Check Rack replacement status Load samples Identify samples Order tests for each sample Press Start Select First Tube or ContinueList the steps required to process samples Locate sample results in the Stored Data screen Stores up to 600 samples or 3000 test results Use the arrow keys to navigate the Store Data screen The Sample information screen displays date, time, ID number, and rack number and position. Graph key displays the coagulation curve Analysis errors are displayed on the Graph screen as ERR [ ] with a number indicating the error. Press the Info. key to see the error name. Press the right arrow key to see more test parameters Select Next to continue. Select the image areas below to learn more. The sample processing procedure varies based on your host computer availability. This section will cover: Sample processing with a bi-directional host interface Manually processing barcoded samples Manually processing non-barcoded samples Note: The sample barcode reader is an optional feature on the Sysmex® CA-600 Series System. If your system does not have a sample barcode reader, refer to the manually processing non-barcoded samples section of this course. Select Next to continue. To process samples while connected to a bi-directional host interface: Load samples in a rack Press Start Note: The sample barcode reader is an optional feature on the Sysmex® CA-600 Series System. If your system does not have a sample barcode reader, refer to the manually processing non-barcoded samples section of this course. Processing with Bi-directional interface Learn how to process samples with a bi-directional interface. Checklist TitleChecklist TypeChecklist ContentCheck Rack replacement statusHTML Verify that "Replace Rack? YES" is displayed at the top of the main menu screen before opening the drawer. Select each checkbox to learn more about processing samples with a bi-directional interface. Load samplesHTML If the media does not automatically start, select the play arrow to begin. Start AnalysisSimulationInstructions:If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Flash File:/content/generator/Course_90004780/sim_CA600_BidirectionalStartAnalysis__9/sim_CA600_BidirectionalStartAnalysis__9.swfHTML5 File:/content/generator/Course_90004780/sim_CA600_BidirectionalStartAnalysis__9/index.htmlPDF File: To process barcoded samples without a bi-directional host interface: Load samples in a rack Order the test Press Start Note: The sample barcode reader is an optional feature on the Sysmex® CA-600 Series System. If your system does not have a sample barcode reader, refer to the manually processing non-barcoded samples section of this course. Manually processing barcoded samples Learn how to manually process barcoded samples. Checklist TitleChecklist TypeChecklist ContentCheck Rack replacement statusHTML Check this area of the screen to determine if you can add more samples to the rack. It should say "Replace Rack? YES" before opening the drawer. Select each checkbox to learn more about manually processing barcoded samples. Load SamplesHTML If the media does not automatically start, select the play arrow to begin. Start AnalysisSimulationInstructions:If the media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004780/sim_CA600_BarcodeStartAnalysis__9/sim_CA600_BarcodeStartAnalysis__9.swfHTML5 File:/content/generator/Course_90004780/sim_CA600_BarcodeStartAnalysis__9/index.htmlPDF File: Congratulations. You have completed the CLINITEK Status® + Instrument Setup online training course. Once you have reviewed the information on this page, you may proceed to the assessment. To process non-barcoded samples: Load samples in a rack Manually enter the sample ID Order the test Press Start Processing manually with non-barcoded samples. Learn how to manually process non-barcoded samples. Checklist TitleChecklist TypeChecklist ContentCheck Rack replacement statusHTML Check this area of the screen to determine if you can add more samples to the rack. It should say "Replace Rack? YES" before opening the drawer. Select each checkbox to learn more about processing samples without barcodes. Load SamplesHTML If the media does not automatically start, select the play arrow to begin. Start AnalysisSimulationInstructions:If the media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004780/sim_CA600_NonBarcodeStartAnalysis__9/sim_CA600_NonBarcodeStartAnalysis__9.swfHTML5 File:/content/generator/Course_90004780/sim_CA600_NonBarcodeStartAnalysis__9/index.htmlPDF File: Stored Data: Holds results for up to 600 samples or 3000 tests Displays analysis errors Stores the coagulation curves for each test Locate Stored Data Learn about Stored Data. Instructions:If the media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004780/sim_CA600_StoredData__9/sim_CA600_StoredData__9.swfHTML5 File:/content/generator/Course_90004780/sim_CA600_StoredData__9/index.htmlPDF File: