Tim Planning Suite (Set-n-Go) - Numaris X
This Job Aid reviews Tim Planning Suite (Set-n-Go) workflow for multi-slice measurements with multiple table moves.
Tim Planning Suite with Set-n-Go Numaris X - Job Aid Tim Planning Suite with Set-n-Go – Numaris X This Job Aid reviews workflow to facilitate planning and evaluating multi-slice measurements. Group individual measurements or combine examinations with multiple table moves using Tim Planning Suite (Set-n-Go). Prerequisites for Set-n-Go Protocols • Distortion Correction – On (Default) o Automatically set to 2D Distortion Correction • (e.g., Resolution > Filter Image Parameter Card) • Positioning Mode – ISO Mode must be selected • Sagittal and Coronal Slices o Hints: Required for Composing to work • Angle – Don’t Angle ±1° • Overlap – Minimum of 50 mm required Dot Cockpit – Create a Set-n-Go Protocol (e.g., Whole Spine) 1. Open Dot Cockpit Icon Dot Cockpit 2. Select Whole Spine Protocol Dot Cockpit - Explorer Press |F11| to e) a. Select Program Editor > Edit Explorer Program Editor b. Open Sagittal T1 or T2 Sequence Browse Import Expor Edit Simulate SIEMENS ... >> whole-spine >> library >> T1 I_t1_tse_dark-fluid_sag 03:58 Il t1 tse dark-fluid_sag 04:38 >head > c-spine IlI t1_tse_dark-fluid_sag 04:38 >t-spine -spine whole-spine I_t1_tse_sag 04:53 clinical libraries library Il_t1 tse_sag 04:15 localizer T1 Ill_t1_tse_sag 03:58 T2 fast > neck soft tissue >thorax I_t1_tse_sag_fast 01:48 >heart breas Il_t1_tse sag_fast 01:29 abdomen Ill t1_tse_sag_fast 01:29 pelvis female > pelvis male set-n-go tmj > shoulder t1_tse_sag_I-III 13:06 elbow Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/20021 | HOOD05162003193732 Healthineers Job Aid | MR Tim Planning Suite (Set-n-Go) – Numaris X Effective Date: 05/31/2021 | HOOD05162003193732 3. Select Geometry > Tim Planning Suite a. Select Set-n-Go Protocol b. Select Inline Composing c. Step – add number of table moves (steps) needed i. Select [+] – adds Step to End of List ii. Select [-] – removes Step d. Select Composing Function i. Spine (e.g., Spine, Angio, Adaptive, Diffusion) e. Select OK – saves changes f. Note: Repeat for Steps for each sequence in protocol (e.g., T1, T2, etc.) Routine Contrast Resolution Geometry Systen hysio Inline Sequence Common AutoAlign Navigator Saturation Tim Planning Suite Set-n-Go Protocol V Inline Composing M Step Normalize Off Table Position 690 - mm Save non-normalized Composing Function Spine Series Description t2_sag A WN - A Dot Cockpit - Explorer 4. Save Program As – when fin- Explorer Program Editor ished building Whole-Spine Browse Import Export Edit Simulate Set-n-Go Protocol X Simulation .. >> Whole Spine >> Spine >> Whole Spine Set-n-Go Dot Whole Spine Dot Engine Basic P ... V Strategy Whole Spine I AAspine scout 01:36 Spine ® Spine Scout Whole Spine t2 tse sag 09:12 1 Whole Spine Set-n-Go Spine Positioning AutoAlign Verification Spine Verification I t1 tse sag 09:32 1 Spine Positioning I t2 tse stir sag 11:04 1 Spine Positioning Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/2021 | HOOD05162003193732 Healthineers Page 2 of 6 Job Aid | MR Tim Planning Suite (Set-n-Go) – Numaris X Effective Date: 05/31/2021 | HOOD05162003193732 Exam UI – Tim Planning Suite Set-n-Go Workflow (e.g., Whole Spine) 1. Whole Spine – Set-n-Go Workflow a. Inline Composing [On] – combines multiple data sets into one series b. Open Sagittal Sequence i. Position Sagittal Slices and Saturation Band ii. Select Flyout Toolbar > Cog Wheel > Overlap EO= Add Slice Group Point Radial Saturat. Stack H. Gap 4. Line Mode Package Over mage Ref. Lines Coils Table Line Adj. c. Overlap – Check amount of Overlap i. Minimum of 50 mm overlap recommended to compose images d. FoV – Check Alignment i. Select Align FoV Icon – aligns FoV & overlaps all steps in a set-n-go protocol ii. Select OK e. Select GO – Run Sagittal Sequences Overlap ? X Overlap 50 + mm Align Parallel For OK Cancel 2. Open Axial Sequence a. Position Axial Slices b. Select Flyout Toolbar > Cog Wheel > Overlap i. FoV – Check Alignment 1. Select Align Parallel icon 2. Select OK c. Select GO – Run Axial Sequences Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/2021 | HOOD05162003193732 Healthineers Page 3 of 6 Job Aid | MR Tim Planning Suite (Set-n-Go) – Numaris X Effective Date: 05/31/2021 | HOOD05162003193732 3. Run Entire Whole-Spine Set-n-Go Protocol Whole Spine Dot Engine a. Hint – do not remove the patient from ISO € + the table until the protocol is saved 1.1 LAAspine_scout E b. Right Mouse on Protocol > select 1.2 I_AAspine_scout E SaveAs 1.3 L_AAspine_scout O 1 I AAspine_scout 00:32 2 I_tz_tse_sag Append Insert 3 % AutoAlign Ver Append Pause ... Ctrl+Insert 4 L_t1_tse_sag Insert Table Positioning Strategy 5 I_t2_tse_stir Repeat Repeat and Open Rerun from here Rerun from here with ... Delete Skip K Stop Copy Parameters ... Update Copy Reference Remove Copy Reference Cut Ctrl+X Copy Ctrl+C Paste Ctrl+V Delete Del Clear All Shift+Del Select Tree Save as ... Ctrl+S c. Select Region Edit Properties ... Alt+Enter d. e. Select Exam f. Enter Program Name i. Name – enter name of protocol (e.g., Whole Spine Set-n-Go) ii. Select Save Save as USER Whole Spine >L-Spine Pelvis Female Pelvis Male Prostate T-spine Whole Spine Spine >Wrist - Whole Body Name Whole Spine Set-n-Go Save Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/2021 | HOOD05162003193732 Healthineers Page 4 of 6 Job Aid | MR Tim Planning Suite (Set-n-Go) – Numaris X Effective Date: 05/31/2021 | HOOD05162003193732 Tim Planning Suite Parameter Card 1. Geometry > Tim Planning Suite Parameter Card a. Set-n-Go Protocol – indicates if Set-n-Go protocol is selected/deselected b. Step – Indicates current step number in Set-n-Go protocol i. [+] Adds a step to end of list ii. [-] Deletes current step c. Table Position – table position where sequence is measured i. H – Moves Table in Head Direction in mm ii. F – Moves Table in Feet Direction in mm iii. Note – Zero point defined by initial table position of first measurement of a se- ries block d. Inline Composing – combines all images from multiple table moves (steps) for an orien- tation or weighting into a complete image (e.g., C, T, and L spine combined) e. Normalize – Off (Default) – reduces image intensity variation for whole body diffusion measurements. (e.g., used for composed whole body diffusion) f. Save Non-normalized –Saves Normalized and Non-normalized images to Patient Browser g. Composing Function – select an option i. Spine – based on Bone Structure, for Composing Spine Images ii. Angio – based on Vessel Structure, for an Overview of Vessels iii. Adaptive – based on elastic matching • Corrects b0 induced inhomogeneities in image areas beyond magnetic homogeneity volume. (e.g., Abdomen, Long Bones) iv. Diffusion – corrects phase encoding direction shifts caused by different adjust- ment parameters for steps in a set-n-go protocol. (e.g., Axial Whole-Body Diffu- sion) h. Series Description – defaults to name of series open (e.g., t1_sag, t2_sag) Routine Contrast Resolution Geometry System Physio Inline Sequence Common AutoAlign Navigator Saturation Tim Planning Suite Set-n-Go Protocol V Inline Composing M Step Normalize Off Table Position 230 mm Save non-normalized v Composing Function Spine Series Description t1_sag Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/2021 | HOOD05162003193732 Healthineers Page 5 of 6 Job Aid | MR Tim Planning Suite (Set-n-Go) – Numaris X Effective Date: 05/31/2021 | HOOD05162003193732 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/31/2021 | HOOD05162003193732 Healthineers Page 6 of 6
- MR
- Tim
- planning
- suite
- set-n-go
- numaris x