Turn on FAST 3D in the Scan Protocol Assistant
Turn on FAST 3D in the Scan Protocol Assistant Computed Tomography 1. From the drop down menu, select Insert View Setup Image Options System Help Version. Options > Configuration > Scan License. Protocol Assistant File Browser. SOMATOM LifeNet Maintenance ... Report Conversion Configuration e-Logbook Auto Expose Configuration Configuration Service Osteo CT Neuro PCT Scan Protocol Assistant Scan Protocol Assistant 2. In the Scan Protocol Assistant, select Scan Protocol Assistant Change Parameters and click the Next ar- 2 3 4 5 row at the bottom. What do you want to do ? Scan protocols Manipulate scan protocols (cut / copy / paste / delete) . Change parameters Import user scan protocols Export scan protocols . Restore scan protocols to Siemens default Contrast protocols · Define contrast protocols List / import / export contrast protocols 3. Select Customized Scan Protocols to view only the site-specific customized protocols, and click the Next arrow again at the bottom. Select the scan protocols you want to change · Adult · Child Select all protocols Axial recon jobs Protocols with ECG Interventional protocols Customized scan protocols Select invalid protocols 3D recon jobs Protocols with Dual Source Protocols with Dual Energy ADMIRE recon jobs Respiratory protocols Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 01/04/2019 | HOOD/HILS HOOD05162002978756 Job Aid | Turn on FAST 3D Effective Date: 01/04/2019 | HOOD/HILS HOOD05162002978756 4. Select Recon to view just the reconstruction jobs of the customized protocols. Protocol Topogram Scan Recon Auto tasking Trigger 5. Deselect the checkbox for Axial Recon Jobs Spiral scans leaving only 3D Recon Jobs selected, and ena- Axial recon jobs v 3D recon jobs ble the FAST 3D checkbox below. Type SP oblique ADMIRE M Algorithm 141s medium + Window Abdomen FOV 300 x2 FAST 3D fili 6. Jump to Step 4 > Confirmation. Scan Protocol Assistant X 1 2 3 4 5 Confirmation 7. The protocol changes will be represented by Old Values vs. New Values. Click the Yes icon to save the changes. Scan protocols with changes: Apply Old Value New Value Do you want to save these changes? 01 ABD FAST3D AbdRoutine Recon 2 Yes FAST 3D MIOff MIOn Recon 3 FAST 3D MIOf MIOn Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 Job Aid | Turn on FAST 3D Effective Date: 01/04/2019 | HOOD/HILS HOOD05162002978756 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3
- Turn on FAST 3D in the Scan Protocol Assistant