Advances in Breast Imaging - Introduction Online Training
This introduction is part of the Advances in Breast Imaging series. The Advances in Breast Imaging series consists of several online trainings which are available free of charge.
The training covers the following topics:
- Introduction of the overall course content and the clinical experts
- Introduction to breast imaging, mammography and digital breast tomosynthesis
This training includes 2 videos with presentations and hints how to use the online training.
Continue Continue Welcome Advances in Breast Imaging Online Training In this and seven other online training courses, we offer you comprehensive insights into the world of wide-angle Digital Breast Tomosynthesis (wa-DBT) and Titanium Contrast Enhanced Mammography (TiCEM) . Course Content 1 Introduction to Breast Imaging 4 General Information 3 The Clinical Experts 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Welcome Reference Studies Following its market introduction in 2009, several clinical studies on Digital Breast Tomosynthesis have proceeded to demonstrate the value of this technique for breast imaging. For a list of Siemens Healthineers-related reference studies shown in this WBT, download the PDF file xp_tomosynthesis_bibliography_HOOD05162003000509.pdf under “Resources” in the upper right corner on this page. Course Content Technical background and image quality of wa-DBT Clinical basics Guidance on how to read Morphology of lesions in 2D and 3D Practical tips for using DBT biopsy TiCEM: A functional imaging method DBT in screening including AI-based CAD Short tests for repetition and self-check Course reviews and final tests Course Content The Clinical Experts Five faces – five of our most experienced clinical experts. They will demonstrate how to use wide-angle Digital Breast Tomosynthesis (wa-DBT) and Titanium Contrast Enhanced Mammography (TiCEM) in the daily routine. All presentations were recorded at home offices via the Internet: Their picture and sound quality may vary. Select the steps or images on the right to listen to the introductions. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 The Clinical Experts Henny Rijken 5 Previously Training and QA Director at LRCB - Dutch Expert Centre for Screening Clinical Expert at ScreenPoint Medical Nijmegen, The Netherlands Lecture in this training: AI in breast screening and diagnostics – case discussions Prof. Dr. Luis Pina 4 Breast Imaging Department (Radiología mamaria) Clínica Universidad de Navarra Pamplona, Spain Lectures in these trainings: Introduction to X-ray based breast imaging DBT-guided biopsy Introduction to Titanium Contrast Enhanced Mammography (TiCEM) Several case discussions Prof. Dr. Chantal Van Ongeval 3 Radiology department University Hospitals Leuven Belgium Lectures in these trainings: Technical background and image quality of a wide-angle Digital Breast Tomosynthesis (wa-DBT) Wide-angle DBT in the clinical routine – Practical hints Wide-angle DBT in screening Several case discussions Prof. Dr. Nico Karssemeijer 2 ScreenPoint Medical Radboud University Medical Centre Nijmegen The Netherlands Lecture in this training: AI in breast screening and diagnostics – the evidence and clinical implementation Dr. Maria Bernathova Department of Biomedical Imaging and Image-guided Therapy Medical University of Vienna Austria Lectures in these trainings: Wide-angle DBT in the clinical routine Morphology of lesions: 2D FFDM vs. 3D wide-angle DBT Introduction to Titanium Contrast Enhanced Mammography (TiCEM) Several case discussions 1 General Information General Information Here you will find some information to the quality of the display of clinical images in the presentations and the possibility to use our glossary. Select the tab arrows on the right for more information. Optimal Video Size Clinical Images in Online Media Reference Studies Glossary General Information Following its market introduction in 2009, several clinical studies on Digital Breast Tomosynthesis have proceeded to demonstrate the value of this technique for breast imaging. For a list of Siemens Healthineers-related reference studies shown in this WBT, download the PDF file XP_Tomosynthesis_Bibliography.pdf under “Resources” in the upper right corner on this page. Reference Studies Glossary You come across abbreviations in the lecture and don't know what they mean? Then take a look at our glossary. Here we have collected many abbreviations related to our specialist area. You will find access to the glossary in each of the web-based training courses on the left above the navigation menu. Due to high data volume but limited bandwidth the mammography and tomosynthesis data sets cannot be loaded in their original size and resolution in this online presentation. The images do by no means achieve the diagnostic quality that is clinically required, especially for evaluating mammography examinations. Furthermore, the image processing software and hardware is continuously being developed and improved. The depicted clinical case studies have not always been acquired with the latest technology and do not automatically reflect the latest state of development. This is also influenced by the specific hospital environment, point in time and patient mix. In clinical routine, the positioning of the breast must be adapted to the clinical conditions; not every patient can be positioned according to ideal criteria. Clinical Images in Online Media Please note: For an optimal display of the recordings of the clinical applications, we recommend to enlarge the videos to full screen by the video control bar. Optimal Video Size Introduction and Overview Introduction to Breast Imaging Why and how do we perform breast cancer imaging? What does mammography do and what are its limitations? Why was tomosynthesis developed and what can be expected from it? Introduction and Overview Introduction to Breast Imaging Prof. Dr. Luis Pina Clínica Universidad de Navarra, Pamplona, Spain Introduction to Breast Imaging 00_Intro_01_Intro-to-breast-imaging.mp4 Mammography and Breast Tomosynthesis Prof. Dr. Luis Pina Clínica Universidad de Navarra, Pamplona, Spain Mammography and Breast Tomosynthesis 00_Intro_02_Overview_Mammography-Tomosynthesis_CORRECTED.mp4 Outro The herein illustrated statements made by Siemens Healthineers customers and physicians are based on their own and discrete opinion. The speaker is responsible for obtaining permission to use any previously published figures or tables. The speaker is also responsible for obtaining permission to reproduce any photograph showing recognizable persons. The statements by Siemens Healthineers customers described herein are based on results that were achieved in the customer's unique setting. Since there is no "typical" setting and many variables exist there can be no guarantee that other customers will achieve the same results. Some products/features (here mentioned) are not necessarily commercially available in all countries. Due to regulatory reasons their availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Disclaimer Exit In this introduction, we’ve given you an overview of what to expect in the online training series “Advances in breast imaging.” We wish you a lot of fun and success! Completion olt_adv-breast-imaging_00_introduction_en_v1 XP Tomosynthesis Bibliography 2D Two-dimensional 3D Three-dimensional AI Artificial Intelligence AUC Area Under the Curve BPE Background Parenchymal Enhancement CAD Computer Aided Detection CC Cranio-caudal CEM Contrast Enhanced Mammography CESM Contrast Enhanced Spectral Mammography CNB Core Needle Biopsy DBT Digital Breast Tomosynthesis DCIS Ductal carcinoma in situ DM Digital Mammography FFDM Full Field Digital Mammography FN False Negative FP False Positive i.m. intramuscular IDC Invasive ductal carcinoma ILC Invasive lobular carcinoma IN Insight = Sythetic Mammogram for wide-angle Tomosynthesis IT Information Technology MAG Magnification View MB Megabyte MG Mammogramm ML Medio-lateral MLO Medio-lateral-oblique MP Megapixel MRI Magnetic Resonance Imaging NCB Needle Core Biopsy NPV Negative Predictive Value PPV Positive Predictive Value pRCT Prospective, Randomized, Controlled Trial ROC Receiver Operating Characteristic STX Stereotaxis TiCEM Titanium Contrast Enhanced Mammography TN True Negative TP True Positive US Ultrasound wa-DBT wide-angle Digital Breast Tomosynthesis WBT Web-based Training 1.1 Welcome 1.2 Course Content 1.3 The Clinical Experts 2.1 General Information 3.1 Introduction and Overview 3.2 Introduction to Breast Imaging 3.3 Mammography and Breast Tomosynthesis 4.1 Disclaimer 4.2 Completion
- breast tomosynthesis
- DBT
- wide-angle tomosynthesis
- tomosynthesis
- FFDM
- mammography