CLINITEK Novus™ Automated Urine Chemistry Analyzer Sample Processing Online Training
Identify the steps needed to prepare the system for running samples. Identify the steps needed to prepare the samples for running on the analyzer. Recall how to run samples using the rack handler and STAT mode. Recall how to review the results, print patient reports and send the sample results to the LIS. This clinical laboratory training qualifies for continuing education units (CEU).
Upon successful completion of this course you will be able to, identify system hardware components, navigate the system software, list the safety considerations on the Viva ProE system, and describe the Emit principle. Select next to continue. Welcome to the CLINITEK Novus™ Automated Urine Chemistry Analyzer Sample Processing online training course. This urine chemistry system provides results for various chemical and physical properties of urine. Select Next to continue. Identify the steps needed to prepare the samples Identify the steps needed to prepare the system for running samples Recall how to review, print and send the sample results Recall how to run samples using the rack handler and STAT mode Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the CLINITEK Novus™ System Overview online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Prepare the system for running samples If the system is Off follow the steps in the Operator's Guide to power it on If the system displays Not Ready review the messages in the Status Log Check the status of the reagent cards Check the supply of rinse Check the card waste container and the liquid waste container Check the paper supply in the printer Prepare the samples Allow samples to reach room temperature Mix each sample thoroughly Do not test samples that are visibly bloody, mucoid or foamy Pour at least two mL of sample into each tube Test samples within two hours of collection Run samples using the rack handler and STAT mode Samples are routinely run on the rack handler During patient testing on the rack handler a STAT sample can be tested in the STAT holder Review, print and send the sample results The Patient Results Details screen displays sample information and results Navigate to the patient results either at the end of a run or by navigating from the Home screen Print patient reports or a summary of sample ID's Resend samples to the LIS from the Patient Results or Results Details screens Select Next to continue. Após a conclusão deste curso, você será capaz de localizar e identificar a função de cada componente do sistema, identificar e localizar os consumíveis, e navegar pelas Telas: Home, Esferas e Reagente, Ajuda e LIS. Selecione Next para continuar. The system is ready for testing when the Home screen displays Ready in the Status Bar. Perform the following system checks before running samples: If the system is Off follow the steps in the Operator's Guide to power it on If the system displays Not Ready review the messages in the Status Log Check the status of the reagent cards Check the supply of rinse Check the card waste container and the liquid waste container Check the paper supply in the printer Select Next to continue. Follow the instructions in the Operator's Guide to power the system on. If the system was powered off completely, press the power switch on the back of the system to the On position. On the right side of the system, press the On button. Powering on the System Learn about powering on the system. Checklist TitleChecklist TypeChecklist ContentPress the Power SwitchHTML If the system was powered off completely press the power switch on the back of the system to the on position. Select each checkbox to learn more about powering on the system. Press the On ButtonHTML On the right side of the system press the On button. The screen is blank for approximately forty five seconds while the system performs a self-test and loads the software. Check the Status BarHTML When the Home screen displays, the Status bar should indicate a Ready status for the system. Check the Status Log for warning messages if Not Ready is displayed. When complete, select the X in the upper-right corner to close the window and continue. The risk factors that are associated with DDH are: the female sex. DDH is four to eight times more common in females, due to an increase in estrogen. Family history; neonates with a family history of a sibling with DDH have a 6% chance of developing developmental dysplasia of the hip and neonates with a family history of appearance with DDH have a 12% chance of developing the disease. Breach presentation, multiple gestations and physicians will refer an infant in for a hip ultrasound, if a hip clip is found on the clinical exam. The Status Log displays warning messages which help you troubleshoot the system. Review the messages in the Status Log to identify the causes for a Not Ready status. Status Log Learn about the Status Log. Tab TitleTextYellow A yellow warning message requires you to take an action before patient testing can begin. Example: The cassette is empty To troubleshoot a yellow warning message: Select the message in the Status log Read the details of the message Select OK Perform the corrective action steps provided in the details. White A white warning message indicates that a warning condition exists. Patient samples can be run on the system. Example: The number of tests remaining is low. When complete, select the X in the upper-right corner to close the window and continue. The transverse view or position is used to show the stability of the hip. The stress method or the Barlow maneuver which is the real time ultrasound imaging can be performed in this view, where the femur is flexed and adducted while applying posterior pressure. In the transverse view, the infant is in an oblique position, the knee is flexed 90 degrees and the transducer is rotated 90 degrees from the coronal plane. The femoral head should be centered on the tri-radiate cartilage. Again this is the view where the stress or the Barlow maneuver can be performed. The SG Well must be cleaned every twenty-four hours. Cleaning the SG Well Learn about cleaning the SG Well. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90005995/1_sim_CN_SGWellClean_training3_800x600_9/1_sim_CN_SGWellClean_training3_800x600_9.swfHTML5 File:/content/generator/Course_90005995/1_sim_CN_SGWellClean_training3_800x600_9/index.htmlPDF File: The Home screen displays the following information about the status of the reagent cassette: Tests Remaining Cassette Type On board Stability Note: An opened cassette must be loaded within ten minutes. Loading a Reagent Cassette Learn about loading a reagent cassette. Checklist TitleChecklist TypeChecklist ContentSelect Load & UnloadHTML Select System > Load & Unload Select each checkbox to learn more about loading reagent cassettes. Select YesHTML Select Yes to confirm unloading of a cassette. Open CoverHTML Open the system cover. Open Cassette DoorHTML Open the cassette door. Select the play arrow to begin video. Remove CassetteHTML Remove the cassette. Select the play arrow to begin video. Prepare New CassetteHTML Prepare the new cassette: Use the foil tab to peel the foil seal off the tray Remove the cassette from the tray Pull the shipping card out of the cassette Select the play arrow to begin video. Load CassetteHTML Load the new cassette. Select the play arrow to begin video. Close and Lock DoorHTML Close the door and turn the lock clockwise to lock the door. Close CoverHTML Close the system cover. The system reads the lot number and expiration date from the cassette. When complete, select the X in the upper-right corner to close the window and continue. The system is configured with either an internal rinse bottle or an external rinse bottle. The internal rinse bottle holds rinse solution for one full cassette. The rinse level indicator on the Home screen turns yellow when the internal rinse bottle is empty. The external waste bottle must be checked visually. Filling the Internal Rinse Bottle Learn about filling the internal rinse bottle. Slide NumberText BlocksCalloutsAudio ScriptImage File1Remove racks from the rack handler and then release the latch and pull the drawer toward you sliding the drawer all the way out of the slot.Select Next to continue. Note: If audio does not automatically start, select the play arrow in the top left to begin.After removing racks from the rack handler release the latch from the rinse drawer. Pull the rinse drawer toward you and then slide the drawer all the way out of the slot.2Remove the cap.Select Next to continue. Turn the rinse bottle cap counterclockwise and remove it.3Empty remaining rinse. Select Next to continue.Empty the remaining rinse solution from the rinse bottle. Dispose of the rinse solution according to your laboratory guidelines.4Fill the rinse bottle with distilled or deionized water. Select Next to continue. Fill the rinse bottle with one thousand milliliters of distilled or deionized water. 5Add 2 mL of CLINITEK Novus Rinse Additive and swirl the bottle gently to mix. Select Next to continue. Add 2 milliliters of CLINITEK Novus rinse additive and then swirl the bottle gently to mix. 6Replace the cap. Select Next to continue. Place the cap back on the rinse bottle and turn it clockwise, making it finger tight.7 Slide the rinse drawer into the slot. Select Next to continue. Slide the drawer into the slot until the drawer is fully closed and latched.8Prime the pump.When complete, select the X in the upper-right corner to close the window and continue.From the Home screen select System and then Prime Pump. Filling the External Rinse Bottle Learn about filling the external rinse bottle. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Disconnect the rinse tubing. Select Next to continue. Note: If audio does not automatically start, select the play arrow in the top left to begin.Disconnect the rinse tubing from the external rinse bottle.2 Empty the remaining rinse solution. Select Next to continue. Empty the remaining rinse solution from the rinse bottle. Dispose of the rinse solution according to your laboratory guidelines.3 Fill the rinse bottle with distilled or deionized water. Select Next to continue. Fill the rinse bottle with one thousand milliliters of distilled or deionized water. 4 Add 2 mL of CLINITEK Novus Rinse Additive and swirl the bottle gently to mix. Select Next to continue. Add 2 milliliters of CLINITEK Novus rinse additive and then swirl the bottle gently to mix. 5 Reconnect the tubing. Select Next to continue. Reconnect the rinse solution tubing to the external rinse bottle.6 Prime the pump. When complete, select the X in the upper-right corner to close the window and continue.From the Home screen select System and then Prime Pump to prime the rinse through the lines. Agora, vamos discutir os painéis do software do ADVIA ® mil e oitocentos. Quando o sistema estiver operacional, os painéis de software estarão sempre visíveis no topo da tela. Existem dois painéis distintos, o painel de operação e o painel menu. O operador utiliza o painel de operação para executar atividades e o painel menu, para visualizar os dados e inserir informações. Veja o Painel operacional e o Menu. Quando terminar, selecione Next para continuar. The used test cards slide into the card waste drawer which holds test cards for one full cassette. The system detects when the drawer is full. Empty the Card Waste Drawer Learn about how to empty the card waste drawer. Checklist TitleChecklist TypeChecklist ContentRemove Card Waste DrawerHTML Remove the racks from the rack handler and then remove the card waste drawer. Select the play arrow to begin video. Select each checkbox to learn more about emptying the card waste drawer. Dispose of CardsHTML Empty the cards according to your laboratory guidelines for handling waste. Clean Card Waste DrawerHTML Clean the card waste drawer. Select the play arrow to begin video. Replace DrawerHTML Slide the drawer into the slot. Select the play arrow to begin video. When complete, select the X in the upper-right corner to close the window and continue. O botão Reagent dá acesso a janela "Reagent Inventory". O conteúdo dos carrosséis de reagentes 1 e 2 são exibidos com informações necessárias, como por exemplo, o número de testes disponíveis, número de lote, status da calibração, estabilidade dos reagentes a bordo, a posição no carrossel e data de expiração. Nesta tela, é possível executar uma verificação dos códigos de barras e imprimir as necessidades do inventário. Se o programa ADVIA QC estiver sendo utilizado, será indicado nesta tela também o status do CQ para cada reagente. Esta janela permanece aberta e minimizada na barra de tarefas para facilitar o acesso pelo operador e é atualizada dinâmicamente. Selecione o link abaixo para saber mais sobre as telas Reagent Inventory e Reagent Containers Settings. The system is configured with either an internal waste bottle or an external waste bottle. The internal liquid waste container holds waste for one full cassette. The Home screen displays a yellow waste indicator when the waste is full. If using an external waste container check the container periodically as the system will not provide the status of the external waste. Emptying the Internal Waste Bottle Learn about emptying the internal waste bottle. Checklist TitleChecklist TypeChecklist ContentRemove the RacksHTML Remove the racks from the rack handler. Select each checkbox to learn more about emptying the internal waste. Remove Waste BottleHTML Release the latch and pull the waste bottle toward you sliding the drawer all the way out of the slot. Select the play arrow to begin video. Remove CapHTML Turn the bottle cap counterclockwise and remove it. Empty Liquid WasteHTML Empty and dispose of the liquid waste according to your laboratory's guidelines and then replace the cap, making it finger tight. Replace Waste BottleHTML Wipe off the waste bottle and then slide it back into the slot until the drawer is fully closed and latched. Select the play arrow to begin video. When complete, select the X in the upper-right corner to close the window and continue. Emptying the External Waste Bottle Learn about emptying the external waste bottle. Checklist TitleChecklist TypeChecklist ContentDisconnect TubingHTML Disconnect the tubing from the external waste bottle. Select each checkbox to learn more about emptying the external waste. Empty WasteHTML Empty and dispose of the waste according to your laboratory guidelines. Reconnect TubingHTML Wipe off the waste bottle and then reconnect the tubing. When complete, select the X in the upper-right corner to close the window and continue. O Guia do Operador Online é uma ferramenta útil para o operador. Pode ser acessado a partir do ícone de informações, no painel de operação. Para navegar pelo manual, use a barra de ferramentas na parte superior, o quadro de navegação, no lado esquerdo e o quadro de conteúdo, no lado direito. Além disso, muitas janelas possuem um ícone de interrogação, localizado no canto superior direito, que abre automaticamente o Manual do Operador e exibe as informações de determinada janela. Selecione os links abaixo para saber mais sobre o Guia do Operador online Check the supply of paper in the printer before running samples. Select Next to continue. Parabéns! Você concluiu o treinamento online do sistema de química ADVIA mil e oitocentos Resoluções de problemas. Abaixo estão listados os principais pontos que foram apresentados. Reserve um tempo para analisar o material antes de prosseguir para o teste final. Prepare samples for running on the rack handler or the STAT holder according to the following guidelines: Allow samples to reach room temperature Mix each sample thoroughly Do not test samples that are visibly bloody, mucoid or foamy Pour at least two mL of sample into each tube Test samples within two hours of collection Select Next to continue Caso a sua calibração do ISE falhar, vamos analisar as sete causas desses erros e as possíveis soluções. Selecione o link abaixo para saber mais sobre estes passos. Samples are routinely run on the rack handler. During patient testing on the rack handler a STAT sample can be tested in the STAT holder. Running Samples on the Rack Handler Learn about running samples on the Rack Handler. Checklist TitleChecklist TypeChecklist ContentLoad TubesHTML Load tubes with at least 2 mL of sample into a rack with the barcodes facing forward. Make sure the tubes are pushed all the way down in the rack. Select each checkbox to learn more about running samples on the Rack Handler. Load RacksHTML Load the racks. Select the play arrow to begin video. Select StartHTML Select Start from the Home screen. Enter Operator IDHTML Optional: Enter Operator ID by selecting the keys on the keyboard and then enter when done. Review Patient Test Progress ScreenHTML The Patient Test Progress screen displays and continually updates the progress of each sample. Review Patient Missing Data ScreenHTML The Patient Missing Data screen appears for samples with no barcodes or barcode misreads. Select Sample ID. Scan the sample ID with the handheld barcode reader or type it in. When complete, select the X in the upper-right corner to close the window and continue. Running Samples in the STAT Holder Learn about running samples in the STAT holder. Checklist TitleChecklist TypeChecklist ContentPull HolderHTML Pull the holder toward you in the STAT island until it stops. Select the play arrow to begin video. Select each checkbox to learn more about running STAT samples. Place TubeHTML Place the tube in the STAT holder. Push HolderHTML Push the holder toward the system until it stops in the STAT island. Select the play arrow to begin video. Select STATHTML On the Patient Progress screen select STAT. Enter Sample IDHTML On the Patient Missing Data screen select Sample ID. Scan the sample ID with the handheld barcode reader or type it in. When complete, select the X in the upper-right corner to close the window and continue. Ocasionalmente, você pode ter uma falha de calibração fotométrica. Selecione o link abaixo para saber mais sobre como solucionar problemas de falhas nas calibrações fotométricas. The Patient Results Details screen displays sample information and results. Navigate to the patient results either at the end of a run or by navigating from the Home screen. Locating Patient Results at the End of a Run Learn about locating patient results at the end of a run. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90005995/2_sim_CN_ReviewResultsAfterRun_800x600_9/2_sim_CN_ReviewResultsAfterRun_800x600_9.swfHTML5 File:/content/generator/Course_90005995/2_sim_CN_ReviewResultsAfterRun_800x600_9/index.htmlPDF File: Locating Patient Results from the Home Screen Learn about locating patient results from the Home screen. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90005995/3_sim_CN_ReviewFromHome_800x600_9/3_sim_CN_ReviewFromHome_800x600_9.swfHTML5 File:/content/generator/Course_90005995/3_sim_CN_ReviewFromHome_800x600_9/index.htmlPDF File: You have just learned how to locate patient results. Let’s practice what you have learned. Locating Patient Results Practice locating patient results. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90005995/4_sim_CN_ReviewResultsSimYourTurn_800x600_9/4_sim_CN_ReviewResultsSimYourTurn_800x600_9.swfHTML5 File:/content/generator/Course_90005995/4_sim_CN_ReviewResultsSimYourTurn_800x600_9/index.htmlPDF File:
- clini
- novis
- clinical laboratory training