Dual Source CT - Fast temporal resolution video
This video shows the advantages of Dual Source CT in getting artifact-free images with fast temporal resolution.
Disclaimer:
Please note that the learning material is for training purposes only!
For the proper use of the software or hardware, please always use the Operator Manual or Instructions
for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be
used as training material only and shall by no means substitute the Operator Manual. Any material used
in this training will not be updated on a regular basis and does not necessarily reflect the latest version of
the software and hardware available at the time of the training.
The Operator Manual shall be used as your main reference, in particular for relevant safety information
like warnings and cautions.
Note: Some functions shown in this material are optional and might not be part of your system. The
information in this material contains general technical descriptions of specifications and options as well
as standard and optional features that do not always have to be present in individual cases.
The reproduction, transmission or distribution of this training or its contents is not permitted without
express written authority. Offenders will be liable for damages.
All rights, including rights created by patent grant or registration of a utility model or design, are
reserved.
Copyright © Siemens Healthcare GmbH, 2019
Fast temporal resolution powered by dual source ET. Reducing the rotation time as much as possible to minimize motion artifacts is crucial for some patient groups. While single source scanners have gotten faster physical rotation, time restrictions means that they can't cross the 100 milliseconds threshold, so motion artifacts remain a problem. It's a completely different story with dual source CT, because the tubes can work together to help you speed up your scans when you set each tube to perform only 1/4 rotation, you still get a half rotation in total. This enables you to achieve resolutions even below 75 milliseconds. As a result, dual source CT is capable of eliminating motion artifacts even during the most demanding applications. Fast temporal resolution powered by dual source CT. Part of our unmatched scan modes. Dual source CT ready beyond tomorrow.
Single Source Dual Source CT Temporal Temporal Fast temporal resolution resolution resolution The 5 Dual Source CT modes The Source CT modes The S Source CT modes SIEMENS Dual Source Single Source Single Source Fast temporal Turbo Flash Dual Energy Dual Power Adaptive 125-165 ms 125-165 ms 125-165 ms 66-75 ms Source CT resolution 4D spiral ms ms ms Ready beyond tomorrow 100 Healthineers 100 100 powered by Dual Source CT Even below 75 ms
- dual
- source
- ct
- temporal
- resolution
- artifact-free
- fast
- motion
- artifact