Sysmex® CS-5100 System Overview Online Training*

Locate major system components and determine their function to provide the operator the foundation to successfully setup and operate the analyzer. Navigate through software screens for ease in system usability. This clinical laboratory training qualifies for continuing education units (CEU).  *U.S. specific content.

The Sysmex® CS-5100 system is a fully automated blood coagulation analyzer that is designed for the high volume laboratory. Speed: high sample processing throughput to deliver faster diagnosis and monitoring Security: Sample result traceability Capacity: extended walkaway time through high capacity of onboard reagents and consumables to improve lab productivity Consistency: same reagents, consumables, and result correlation with Sysmex® CS family of systems to provide advance patient care Select Next to continue.    Describe the sample processing sequence Distinguish between the different detection methods Identify major hardware components Navigate the software Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the Sysmex® CS-5100 System Overview Online Training course. Listed below are the key points that have been presented.  Take time to review the material before you proceed to the final quiz.  Identify major hardware components External Components Light shield lid- protects sample arms, reagent arms and Reagent table. Must be closed during processing Start button- press to start analysis Mechanical stop switch-immediately stops mechanical movements Sampler-automatically transports sample racks to the aspiration position. Holds 10 racks and 100 samples Cuvette hopper- holds 1000 cuvettes for sample processing. Load cuvettes anytime Power switch- turns power on/off, located below the Sampler Halogen lamp- light source for all assay analysis Internal Components Sample arm A- holds cap piercing probe used for primary dispensing of a sample in normal mode Sample arm B- holds non cap piercing probe used for secondary dispensing of a sample, used also for micro mode Reagent table- circular wheel holding 10 reagent racks, has 40 reagent positions, cooled to 10° C STAT Diluent table- has 5 diluent positions and 5 stat sample positions, at room temperature Reagent arm A- located behind light shield, dispenses activator reagent Reagent arm B- located behind back cover, dispenses trigger reagent Reagent arm C- located behind back cover, dispenses Fibrinogen reagent Dispensing table A- holds sample aliquot cuvettes, dispensed by Sample arm A Dispensing table B- supplies cuvettes to Sample arm B Incubator- holds 36 cuvettes, warms sample cuvettes to 37° C Tube supply catcher - moves cuvettes from Hopper to Dispensing table B, moves sample cuvettes to incubator Detector- 20 channels for analyzing clotting, chromogenic, and immunologic assays, maintained at 37° C Pneumatic Unit- supplies pressure to the system Peripheral Components 2D Barcode reader- Hand held barcode reader used to input calibrator values, PT ISI value, and control lot information Information Processing Unit- also called IPU.  includes 19 inch touchscreen with mouse and computer with Windows 7 IPU Cart- holds IPU, drawers to hold rinse and waste containers Printer Distinguish between the different detection methods Simultaneous Multi-Wavelength Detection- simultaneous multi-wavelength scanning of clotting reactions at 340, 405, 575, 660, and 800 nm. It is possible to obtain a result from an alternative wavelength minimizing repeats Clotting method- detects change in transmitted light, clot time is measured at the 50% point of reaction curve Chromogenic method- process of color emission by a chromogenic synthetic substrate, change in light absorbance is calculated Immunologic- process of antibody-antigen reaction, change in light absorbance is calculated Aggregation* - process of agglutination reactions by platelets, change in light absorbance is calculated *The product is still under development and not commercially available yet. Its future availability cannot be ensured.  Describe the sample processing sequence  Dispensed aliquot cuvette Test cuvette incubated Reagents added Test cuvette analyzed in Detector Test and aliquot cuvettes to cuvette trash box Navigate the software Toolbar- contains shortcut buttons for the main functions View- has icons for main functions as well as icons for Settings, Operation log, and Software version Status bar- displays status of Main Unit, displays error messages, displays help button, displays status of host computer, displays indicators for  temperature, reagents, cuvettes, and rinse water Select Next to continue.                                   The Sysmex® CS-5100 system has a multi-wavelength analysis technology that utilizes 5 wavelengths to perform the following assays: Clotting Chromogenic Immunologic Aggregation* *The product is still under development and not commercially available yet. Its future availability cannot be ensured. Detection Methods Learn about the Detection Methods on the Sysmex® CS-5100 system Tab TitleTextClotting Wavelengths used : 340, 405, 575, 660, 800nm Assays: PT, aPTT, Fibrinogen, Thrombin Time,  Factor assays, Lupus Uses Percent Detection method Detects change in transmitted light Clotting time is measured Clot time read at 50% point of reaction curve     Chromogenic Wavelengths used: 340, 405, 575, 660, 800nm Assays: AT, Heparin, FVIII, FXIII Uses Rate method: Process of color emission by a chromogenic synthetic substrate Change in light absorbance is calculated     Immunologic Wavelengths used: 340, 405, 575, 660, 800nm Assays: D-Dimer Uses Rate method, VLin method Process of antibody-sensitive reagent reacting with antibodies Change in light absorbance is calculated When complete, select the X in the upper-right corner to close the window and continue.   Multi Wavelength Detection Learn more about the Simultaneous Multi-Wavelength Detection system Simultaneous Multi-wavelength Detection System The CS-5100 System provides simultaneous multi-wavelength scanning of clotting reactions at 340, 405, 575, 660, and 800nm.    Since multiple wavelengths can be evaluated by each detector well, a sample with an analysis error in the main wavelength is also evaluated by another wavelength. This function makes it possible to obtain a result on the first attempt thus minimizing repeats.   When complete, select the X in the upper-right corner to close the window and continue.    Sample Processing on the Sysmex® CS-5100 system involves a series of fast movements including: Dispensed aliquot cuvette Test cuvette incubated Reagents added Test cuvette analyzed in Detector Test and aliquot cuvettes to cuvette trash box Sample Processing Sequence Watch the sample processing sequence.   Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. The Sysmex® CS-5100 system software is intuitive and easy to use. The screen has 3 parts: Toolbar View Status bar   Software Overview Learn about the Sysmex® CS-5100 System Software. Instructions:Flash File:/content/generator/Course_90014037/sim_CS51_SoftwareOverview_US_800x600_swf/sim_CS51_SoftwareOverview_US_800x600_swf.htmHTML5 File:/content/generator/Course_90014037/sim_CS51_SoftwareOverview_US_800x600_html5/index.htmlPDF File: The Sysmex® CS-5100 system external components: Light shield lid Start button Sampler Mechanical stop switch Cuvette hopper Power switch Halogen lamp External Components Learn more about the External Components Slide NumberText BlocksCalloutsAudio ScriptImage File1Light shield lid Protects sample arms, reagent arms, reagent table Closed and locked during processing Open to add reagents Open to perform maintenance   Select Next to continue.           Note: If audio does not automatically start, select the play arrow in the top left to begin.The light shield lid protects internal components such as the sample arms, reagent arms, and the reagent table. During processing, the light shield lid is closed and locked for safety. When processing is complete, it can be lifted to add reagents and to perform maintenance. Select Next to continue. 2 Start button Located on the front of the analyzer Press to start analysis Select Next to continue.        Select the number to review the corresponding text.Callouts Start button The start button, located on the front of the instrument, is used to start analysis on the Sysmex® CS-5100 system. A start can also be requested through the software. Select Next to continue.3Mechanical stop switch Press button to immediately stop the instrument's mechanical movement Samples in the detector will continue to be analyzed   Select Next to continue.   Select the number to review the corresponding text.Callouts Mechanical Stop Button The mechanical stop switch is used to immediately stop mechanical movements of the Sysmex CS-5100 system. Samples in the detector will continue to be measured even after the mechanical stop switch is pressed. Select Next to continue.4 Sampler Automatically transports sample racks to the aspiration position Continuous loading of sample racks Load up to 100 samples Capped and uncapped tubes in same rack   Select Next to continue.    The sampler automatically transports sample racks to the aspiration position during sample processing. Racks can be loaded continuously and up to 100 samples can be loaded at a time. Once the samples are aspirated, the rack is moved to the left side of the sampler where it can be removed. Select Next to continue.5 Cuvette hopper Holds 1000 cuvettes Supplies cuvettes for sample processing System alerts when cuvettes running low or empty Load cuvettes anytime   Select Next to continue.     The cuvette hopper holds up to 1000 cuvettes and supplies them to the system for sample processing. The Sysmex® CS-5100 system will alert the operator when cuvettes are running low or are empty. Cuvettes can be added to the hopper at anytime. Even during processing! Select Next to continue.6 Power switch Located below the sampler  Turns power on/off   Select Next to continue.    The power switch is on the front of the system below the sampler. It is used to power the system on and off. Select Next to continue.7Halogen Lamp  Light source for all assay analysis Supplies 5 wavelengths of light: 340nm, 405nm, 575nm, 660nm, 800nm When complete, select the X in the upper-right corner to close the window and continue.   Select the number to review the corresponding text.Callouts Halogen Lamp A halogen lamp is the light source for the Sysmex CS-5100 and is used for all assays. It is located behind a door on the right side of the instrument. The halogen lamp uses a filter wheel to disperse the light into 5 different wavelengths. Congratulations. You completed the overview of external components on the Sysmex CS-5100 system. The Sysmex® CS-5100 system internal components: Sample arm A and B Reagent table STAT Buffer table Reagent arm A, B, C Incubator Detector Pneumatic Unit Internal Components Learn more about the Internal Components Slide NumberText BlocksCalloutsAudio ScriptImage File1 Sample arm A Cap piercing Used for primary dispensing of a sample Normal mode testing Aspirates and dispenses samples and controls Sample arm B Non cap piercing Used for secondary dispensing of sample Micro mode testing Aspirates and dispenses samples, controls, calibrators, and buffers   Select Next to continue.       Select each number to review the corresponding text.   Note: If audio does not automatically start, select the play arrow in the top left to begin.Callouts Sample Arm A Sample Arm B Sample arm A and Sample arm B are located behind the light shield lid. Sample arm A is a cap piercer and is used to aspirate and dispense samples and controls for normal mode testing. Sample arm B is a non cap piercer and is used for secondary dispensing of the sample and for micro mode testing. Sample arm B aspirates and dispenses samples, controls, calibrators and buffers. Select next to continue. 2 Reagent table  Circular wheel holding 10 reagent racks Has 40 reagent positions Automatic barcode reading function Cooled to 10°C STAT Buffer table 5 diluent positions 5 stat positions Automatic barcode reading function Room temperature   Select Next to continue.        Select each number to review the corresponding text.   Callouts Reagent Table STAT Buffer Table The reagent table is centrally located behind the light shield lid. It is a circular wheel that holds 10 reagent racks and has 40 positions available for cleaners, reagents, controls, and calibrators. Automatic positive reagent identification is provided by a barcode reader. The reagent table is cooled to 10 degrees Celsius which provides excellent reagent onboard stability. The stat buffer table is located on the front of the analyzer. It has 5 diluent positions and 5 stat sample positions which are at room temperature. This area also utilizes an automatic barcode reading function to identify diluents and stat samples. Select next to continue. 3Reagent arm A Located behind light shield lid Dispenses activator reagent Reagent arm B Located behind back cover Dispenses trigger reagent Reagent arm C Located behind back cover Dispenses Fibrinogen reagent   Select Next to continue.   Select each number to review the corresponding text. Callouts Reagent Arm A Reagent Arm B Reagent Arm C There are 3 Reagent probes used on the Sysmex® CS-5100 system. All the reagent probes are heated to 37 degrees Celsius and quickly warm the reagents before dispensing. Reagent arm A is located to the right of the Reagent table. Reagent arm A dispenses the activator reagent into the sample cuvette. Reagent arm B and C are located behind the back cover and are not seen by the operator. Reagent arm B dispenses the trigger reagent to the sample cuvette. Reagent arm C dispenses the Thrombin reagent for the Fibrinogen assay. Select next to continue. 4 Dispensing table A Holds sample aliquot cuvettes Dispensed by Sample arm A Normal mode Dispensing table B Supplies cuvettes to Sample arm B Micro mode and secondary dispensing   Select Next to continue.     Select each number to review the corresponding text. Callouts Dispensing Table A Dispensing Table B Dispensing table A is a circular table that surrounds the Reagent Table. This table is used to hold the sample aliquots dispensed by Sample arm A for normal mode testing. Dispensing table B is located on the right side next to the hopper. This table supplies cuvettes to Sample arm B for primary dispensing during micro mode and secondary dispensing during normal mode. Select next to continue. 5 Incubator Warms sample cuvettes to 37° C Holds 36 cuvettes Tube supply catcher Moves new cuvettes from Hopper to Dispensing table B Moves sample cuvettes to incubator Select Next to continue.    Select the number to review the corresponding text. Callouts Incubator Tube Supply Catcher The incubator warms sample cuvettes to 37 degrees Celsius during sample processing and holds 36 cuvettes. The tube supply catcher moves new cuvettes from the hopper to dispensing table B during sample processing. After sample is added to the cuvette, the tube supply catcher moves the sample cuvette to the incubator for warming. Select next to continue. 6Detector 20 channels for clotting, chromogenic, and immunologic assays 8 channels for aggregation assays* Maintained at 37° C   Select Next to continue. *The product is still under development and not commercially available yet. Its future availability cannot be ensured.  Select the number to review the corresponding text. Callouts Detector The detector on the Sysmex® CS-5100 system is located behind the back cover and has 20 channels for analysis of all clotting, chromogenic, and immunologic assays. Of the 20 channels, 8 can also be used for aggregation assays. The detector is maintained at 37° Celcius. Select next to continue. 7 Pneumatic Unit Located behind the left door Supplies pressure to the system When complete, select the X in the upper-right corner to close the window and continue.The pneumatic unit is located behind the left door and supplies pressure to the system. Congratulations. You completed the overview of internal components. The Sysmex® CS-5100 system peripheral components: 2D Barcode reader Information Processing Unit (IPU) Touch screen IPU cart Printer Peripheral Components Learn more about the Peripheral Components. Base ImageHotspotsText BlocksImage FileInformation Processing Unit (IPU) -Computer- Windows 7 operating system -Touchscreen-19 inch screen -Mouse2D Barcode reader -Hand held barcode reader used to input calibrator values, PT ISI , and control informationPrinter -Patient results -Calibration curves -QC reportsIPU Cart  -Computer, Touchscreen, mouse -Drawers for 20 L rinse and waste containers The Sysmex® CS-5100 system: External Components Internal Components Peripheral Components External Component Examples A- Light Shield Lid B-Sampler Internal Component Examples C-Sample and Reagent Arms D-Pneumatic Unit Peripheral Component Examples E-Touch Screen F-Rinse and Waste Canisters Select Next to continue.